Arrow IPN921169
Ref CP-07611-P
Arrow IPN921169 (CP-07611-P) is a vascular catheter introduction set (EU MDD Class IIa; FDA Class II; FDA product code DYB, Introducer, catheter) made by Teleflex Incorporated, registered in EUDAMED on 6 Jul 2026 (Basic UDI-DI B-10801902201031), cleared under FDA 510(k) K924607 on 22 Apr 1993 and listed in FDA GUDID since 9 Nov 2022 (UDI-DI 10801902201031), active as of 9 Nov 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-10801902201031 10801902201031 | Date6 Jul 2026 | StatusActive |
| United States | GUDID listing GUDID | Number10801902201031 | Date9 Nov 2022 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK924607 | Date22 Apr 1993 | StatusActive |
Official records
- EUDAMED public site B-10801902201031
- AccessGUDID record 10801902201031
- FDA 510(k) database K924607
Across registries
- EUDAMED Basic UDI-DI B-10801902201031 registered 6 Jul 2026 Active
- FDA 510(k) K924607 decided 22 Apr 1993 Active
- FDA GUDID UDI-DI 10801902201031 listed 9 Nov 2022 Listed
Recalls
-
- Terminated Z-1064-2016
Arrow has issued a recall for these products due to potential packaging damage. The sterility of the products cannot be guaranteed. If non-sterile product is used there is a potential for infection to occur.
-
- Terminated Z-1491-2009
Leakage: Material not lipid resistant, may crack and/or leak. Use of this device with lipid containing solutions or 70% isopropyl alcohol may cause leakage or air embolism.
-
- Terminated Z-0088-04
package lid identifies the contents incorrectly
Timeline
- Cleared FDA 510(k) K924607
- Recall initiated FDA recalls Z-0088-04
- Recall initiated FDA recalls Z-1491-2009
- Recall initiated FDA recalls Z-1064-2016
- Listed FDA GUDID 10801902201031
- Registered EUDAMED B-10801902201031
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Super Arrow-Flex(R) Percutaneous Sheath Introducer Set with Integral Hemostasis Valve/Side Port (accepts .021" - .025" wire) EUDAMEDArrow GUDID
- Generic name
- Vascular catheter introduction set, nonimplantable
- Device name
- Cath Lab Sheath Intro Set
- Model / Ref / Catalog
- CP-07611-P, IPN921169
- Primary DI / UDI-DI
- 10801902201031
- Basic UDI-DI
- B-10801902201031
- 510(k) Number
- FDA product code
- DYB
- EMDN code
- C0502 Cardiovascular introducer sheaths, valved
- GMDN term
- Vascular catheter introduction set, nonimplantable
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 870.1340
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Ireland
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | CP-07611-P | IPN921169 |
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under CARDIOVASCULAR INTRODUCER SHEATHS, VALVED.
- Check-Flo G10103 RCFN-6.0-38-J by COOK INCORPORATED
- SSPC Delivery Catheter 9181 by CenterPoint Systems LLC
- IVA introducers sheat IVA3F by Balt extrusion SAS
- Prelude® 10884450615192 PSI-5F-11/D by Merit Medical Systems, Inc.
- Guiding Sheath (GSQ) GSQ120A5 by Q3 Medical Germany GmbH
- Performer G21107 RCFN-4.0-18-13-RA2.5 by COOK INCORPORATED
- DESTINATION RSR04 by TERUMO MEDICAL CORPORATION
- Prelude® 10884450614454 PSI-7F-23-018NT4/D by Merit Medical Systems, Inc.
- DESTINATION 54-86501 by TERUMO MEDICAL CORPORATION
- Hemostasis Valve 497297 by Argon Medical Devices, Inc.