Skip to content

Arrow IPN031507

by Teleflex Incorporated

Arrow IPN031507 (ES-04706-P) is a centrally-inserted central venous catheter (FDA Class II; FDA product code DQY, Catheter, Percutaneous) made by Teleflex Incorporated, cleared under FDA 510(k) K810962 on 29 Apr 1981 and listed in FDA GUDID since 16 Sep 2016 (UDI-DI 00801902009975), active as of 22 Oct 2026. 2 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

510(k) K810962

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00801902009975 UDI-DI Date16 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK810962 Date29 Apr 1981DecidedStatusActive

Official records

From the FDA record

Device description
Central Venous Catheterization Set with Blue FlexTip (R) Catheter
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K810962 decided 29 Apr 1981 Active
  • FDA GUDID UDI-DI 00801902009975 listed 16 Sep 2016 Listed

Recalls

2 recalls · 1 ongoing · FDA

    • Ongoing Z-2377-2026 FDA Class I initiated 21 Apr 2026

    Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.

    • Terminated Z-1960-2018 FDA Class II initiated 11 Apr 2018

    Product sterility may be compromised due to unsealed packaging.

Timeline

4 dated events

  1. Cleared FDA 510(k) K810962
  2. Listed FDA GUDID 00801902009975
  3. Recall initiated FDA recalls Z-1960-2018
  4. Recall initiated FDA recalls Z-2377-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Arrow
Generic name
Centrally-inserted central venous catheter
Model / Ref / Catalog
IPN031507, ES-04706-P
Primary DI / UDI-DI
00801902009975
510(k) Number
FDA product code
DQY
GMDN term
Centrally-inserted central venous catheter
Device class
Class II
Regulation number
870.1250
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code DQY (CATHETER, PERCUTANEOUS).

Other devices from Teleflex Incorporated

  • Arrow IPNB00820 Open recall

    Class II
  • Arrow IPNB00826 Open recall

    Class II
  • Arrow IPNB00822 Open recall

    Class II
  • Arrow IPNB00827 Open recall

    Class II

See all devices from Teleflex Incorporated →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
Other properties (8, all answered No)