Arrow-Lok 1
by Arrowhead De LLC 19 variants
Arrow-Lok 1 (27-253522) is an orthopaedic bone pin (FDA Class II; FDA product code HTY, Pin, Fixation, Smooth) made by Arrowhead De LLC, cleared under FDA 510(k) K112675 on 12 Dec 2011 (1 earlier submission) and listed in FDA GUDID since 23 Mar 2016 (UDI-DI 00855967006141), active as of 22 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00855967006141 | Date23 Mar 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK112675 | Date12 Dec 2011 | StatusActive |
Official records
- AccessGUDID record 00855967006141
- FDA 510(k) database K112675
- FDA 510(k) database K100926
From the FDA record
- Device description
- ARROW-LOK 2.5-3.5mm / Length 22mm, Angled
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile; sterilise before use (Radiation Sterilization)
Across registries
- FDA 510(k) K112675 decided 12 Dec 2011 Active
- FDA GUDID UDI-DI 00855967006141 listed 23 Mar 2016 Listed
Recalls
-
- Ongoing Z-2958-2026
Implant indicated for fixation of osteotomies, arthrodeses and reconstruction in the lesser toes following corrective procedures, did not undergo required gamma radiation dose audit. A potential reduction in sterility assurance could lead to patient infection.
Timeline
- Cleared FDA 510(k) K100926
- Cleared FDA 510(k) K112675
- Listed FDA GUDID 00855967006141
- Recall initiated FDA recalls Z-2958-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Arrow-Lok
- Generic name
- Orthopaedic bone pin, non-bioabsorbable
- Model / Ref / Catalog
- 1, 27-253522
- Primary DI / UDI-DI
- 00855967006141
- FDA product code
- HTY
- GMDN term
- Orthopaedic bone pin, non-bioabsorbable
- Device class
- Class II
- Regulation number
- 888.3040
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Radiation Sterilization
- Size
- Length — 22 Millimeter
Similar devices in this category
Other devices filed under Orthopaedic bone pin, non-bioabsorbable.
- Affixus® Natural Nail® 110035668 by Zimmer, Inc.
- Kirschner wire K10 NS220 by In2Bones SAS
- NA NK 0014-28 by aap Implantate AG
- Scheker DRUJ DRUJ-KW45 DRUJ-KW54 by APTIS MEDICAL, LLC.
- NA NK 0010-15-2 by aap Implantate AG
- Arthrex® AR-1351L by Arthrex, Inc.
- 7D Surgical Iliac Cross Pin, 150 mm 11-0104 by 7D Surgical ULC
- Arthrex® AR-5050K-1S by Arthrex, Inc.
- ACUMED HRH-0828-S by ACUMED LLC
- Pin S581030065 by Tianjin Zhengtian Medical Instrument Co., Ltd.