# Arthroscope Accessories

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/arthroscope-accessories-hrx>
- Manufacturer: [Stryker Endoscopy](https://devicerts.com/manufacturers/stryker-endoscopy) (United States)
- Name in the registry: ARTHROSCOPE ACCESSORIES
- Device class: Class II (US FDA)
- FDA product code: HRX

## Overview

*AI-generated summary, 2026-09-19. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Arthroscope Accessories are supplementary components designed for use with arthroscopic surgical systems. These accessories facilitate minimally invasive joint procedures by enabling fluid irrigation, suction, and instrument passage through arthroscopic ports, supporting visualization and manipulation within the joint space.

Supplied as reusable items, these accessories are intended for use in orthopedic surgical settings. They are cleared under FDA 510(k) K944210 as substantially equivalent to predicate devices, adhering to traditional review pathways. The product code HRX categorizes them under orthopedic advisory committee classifications, with no specific sterility or MRI safety restrictions noted in the data.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K944210 · decision 1995-02-14 · decision SESE · status: Active

## Recalls

- Z-1927-2011 ·  · terminated · initiated 2011-03-07: Insufficient cleaning instruction were included for the Inflow/outflow Cannula in the user manual.
- Z-0868-2009 ·  · terminated · initiated 2008-12-01: Leak: Leak-resistant barrier may not properly seal and leak when an instrument is inserted, and keep leaking after instrument is removed.
- Z-0652-2009 ·  · terminated · initiated 2008-10-01: Unable to pump fluids. Silicone tubing is stiffer than usual, resulting in motor defect message, leading to inability to pump saline through tubes for surgery.

## Identifiers

- 510(k) Number: K944210 [FDA 510(k)]
- FDA product code: HRX [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 888.1100 [FDA 510(k)]
- Advisory committee: Orthopedic [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Arthroscope Accessories, Stryker Endoscopy. deviCERTS medical device catalogue. https://devicerts.com/devices/arthroscope-accessories-hrx (data as of 2026-11-16).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-26
- Statuses computed as of: 2026-11-16
- JSON: <https://devicerts.com/devices/arthroscope-accessories-hrx.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/arthroscope-accessories-hrx
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.