ARTIS pheno (VE2)
by Siemens Medical Solution USA, Inc.
510(k) K201156
ARTIS pheno (VE2) is a Class II device made by Siemens Medical Solution USA, Inc., cleared under FDA 510(k) K201156 on 29 Jun 2020, active as of 22 Oct 2026. 5 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
4 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK201156 | Date29 Jun 2020 | StatusActive |
Official records
- FDA 510(k) database K201156
Recalls
-
- Ongoing Z-1294-2022
A video signal from one of the transceivers of the Large Display may be lost. In very rare cases, both transceivers of the Large Display could potentially fail which can lead to the loss of both video signals. This issue can sporadically affect the Large Display in the examination room as well as the displays in the control room.
-
- Ongoing Z-0987-2022
Five potential software issues affecting Artis pheno and Artis icono systems in combination with a Siemens Healthineers table or Trumpf/MAQUET table (OEM). The potential software errors are related to the block movements function and manual rotation of the flat detector. Depending on the status of the intervention, the limited functionality may not be sufficient to continue with treatment as planned. This may result in a situation where clinical treatment may be delayed until an additional restart is performed
-
- Ongoing Z-1339-2022
After CT image data from Toshiba is loaded, image mirroring can occur along the horizontal and vertical image axes. If this error occurs, the patient orientation/position may be misinterpreted and result in inappropriate treatment, even if the incorrect visualization is obvious.
-
- Ongoing Z-2029-2021
Software error VE10B -In case of a fault within the drivetrain of an axis and while performing a stepped peripheral imaging (PERISTEPPING/PERIVISION), the C-arm may leave its intended travel path by up to 22 cm (9") result in canceling clinical treatment or to continue treatment on an alternative system
-
- Terminated Z-0515-2022
Four potential software issues with Artis pheno and Artis icono systems with software VE20C: 1. Updated calibration data not saved with measurement after scene+/-; 2. No x-ray possible, system shutdown/restart might be required during intervention; 3. Corrupted Image during Roadmap; 4. Unintended shutdown of Imaging System with UPS (Uninterruptable Power Supply) option
-
- Terminated Z-1497-2021
Siemens has become aware of a potential issue with software version VE20C. Planned procedures may have to be terminated and performed on an alternative x-ray system.
Timeline
- Cleared FDA 510(k) K201156
- Recall initiated FDA recalls Z-1497-2021
- Recall initiated FDA recalls Z-2029-2021
- Recall initiated FDA recalls Z-0515-2022
- Recall initiated FDA recalls Z-0987-2022
- Recall initiated FDA recalls Z-1339-2022
- Recall initiated FDA recalls Z-1294-2022
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- OWB
- Device class
- Class II
- Regulation
- 21 CFR Part 892.1650
- Advisory committee
- Radiology
- FDA decision
- SESE Substantially Equivalent