← Back to catalogue

Asfora Bullet Cage® System

FDA UDI

Class II (US FDA UDI)

by Medical Designs Llc

Identity

Trade Name
Asfora Bullet Cage® System FDA UDI
Generic Name
Metallic spinal interbody fusion cage FDA UDI
Device Name
18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. FDA UDI
Model / Reference
11-9902-FD9 FDA UDI
Description
18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation. FDA UDI

Identifiers

Primary DI / UDI-DI
M364119902FD90 FDA UDI
FDA Product Code
MAX FDA UDI
GMDN Term
Metallic spinal interbody fusion cage FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
888.3080 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

Yes

FDA UDI

Single Use

Yes

FDA UDI

Implantable

Yes

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

No

FDA UDI

Dimensions & Sizes

Size
Outer Diameter — 18 Millimeter FDA UDI
Length — 21 Millimeter FDA UDI

Category: Metallic spinal interbody fusion cage

Asfora Bullet Cage® System by Medical Designs Llc — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Metallic spinal interbody fusion cage.

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Manufacturer
Medical Designs Llc

Sources (1)

  • FDA UDI 11d28017-312c-489c-a874-c4148de3fcf2 35 fields · synced May 30, 2026