Assurity™ PM1240
Assurity™ PM1240 is a Class III device made by St. Jude Medical, Inc., approved under FDA PMA P880086 on 21 Aug 1989 and listed in FDA GUDID since 10 Apr 2017 (UDI-DI 05414734507066), active as of 23 Oct 2026.
Active
Valid until
No expiry
FDA recalls
3 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number05414734507066 | Date10 Apr 2017 | StatusListed |
| United States | FDA PMAAPPR | NumberP880086 | Date21 Aug 1989 | StatusActive |
Official records
- AccessGUDID record 05414734507066
- FDA PMA database P880086
Across registries
- FDA PMA P880086 decided 21 Aug 1989 Active
- FDA GUDID UDI-DI 05414734507066 listed 10 Apr 2017 Listed
Recalls
-
- Ongoing Z-1496-2022
- Ongoing Z-1497-2022
The Merlin" 2 PCS model MER3700 is a portable, dedicated programming system designed to interrogate, program, display data from, and test Abbott Medical implantable medical devices during implant and follow-up.
-
- Ongoing Z-1495-2022
There is a potential for programmer software (Merlin PCS) and remote monitoring software application (Merlin.net) to display overestimated predicted battery longevity for certain pacemakers.
-
- Terminated Z-0430-2012
St. Jude Medical has received reports of out of range pacing lead impedance (PLI) measurements. These measurements are low and out of range (<200 ohms) but measure in range during visits to the clinic. The out of range readings are concluded as false.
-
- Terminated Z-0429-2012
St. Jude Medical has received reports of out of range pacing lead impedance (PLI) measurements.These measurements are low and out of range (<200 ohms) but measure in range during visits to the clinic. The out of range readings are concluded as false.
-
- Terminated Z-0298-2007
- Terminated Z-0296-2007
- Terminated Z-0297-2007
St. Jude Medical has identified a low-frequency anomaly in the software used in the APS III Model 3500/3510 and Merlin PCS Model 3650 programmers that can lead to incorrect reporting of battery voltage, expected battery longevity and Elective Replacement Indicator (ERI) status.
-
- Terminated Z-0052-04
Under certain circumstances, pacemaker has a potential to deliver a short coupled pacing interval of approx. 300 msec (200ppm). It is also possible that a patient may experience (up to max of 12) shorter than anticipated pacing intervals.
Timeline
- Recall initiated FDA recalls Z-0052-04
- Recall initiated FDA recalls Z-0298-2007
- Recall initiated FDA recalls Z-0296-2007
- Recall initiated FDA recalls Z-0297-2007
- Recall initiated FDA recalls Z-0430-2012
- Recall initiated FDA recalls Z-0429-2012
- Listed FDA GUDID 05414734507066
- Recall initiated FDA recalls Z-1496-2022
- Recall initiated FDA recalls Z-1497-2022
- Recall initiated FDA recalls Z-1495-2022
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Trade name
- Assurity™
- Generic name
- Single-chamber implantable pacemaker, rate-responsive
- Model / Ref / Catalog
- PM1240
- Primary DI / UDI-DI
- 05414734507066
- PMA number
- FDA product code
- NVZ
- GMDN term
- Single-chamber implantable pacemaker, rate-responsive
- Device class
- Class III
- GUDID distribution status
- In Commercial Distribution