Atellica CH AlbP 11645753

by Siemens Healthcare Diagnostics Inc.

Ref 11645753Model IVDR_67_TTN_DUB-C_B_REAG_ALBP

Active European Union. Also listed in GUDID (US).

CE IVDR

Valid until

Not listed

EUDAMED holds no validity date

FDA recalls

5 ongoing

Recall on shared 510(k) K151767; other models may be affected

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, GUDID, synced 25 Oct 2026. What this means

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDR EUDAMED Number0405686900760VQ Basic UDI-DI 00630414654003UDI-DIDate15 Jul 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00630414654003 UDI-DI Date18 Mar 2026ListedStatusListed GUDID: in commercial distribution

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

12 recalls · 5 ongoing · FDA

    • Ongoing Z-2027-2025 FDA Class II initiated 22 May 2025 on shared 510(k) K151767

    Contamination of the diluent by sodium hypochlorite (NaOCl) which may impact calibrator, quality control (QC), and patient results for all assays except for sodium, potassium, and chloride.

    • Ongoing Z-1003-2024 FDA Class II initiated 15 Dec 2023 on shared 510(k) K151767

    Potential for a negative bias with quality control (QC) and patient sample results when using the Atellica CH Immunoglobulin M_2 (IgM_2) reagent.

    • Ongoing Z-0449-2022 FDA Class II initiated 18 Nov 2021 on shared 510(k) K151767

    (1)Software (SW) versions V1.25.1 and lower may result in TDef (Test Definition) Parameters for Open Channel Assays reverting to Default Value would shift test results by the magnitude of the implemented Assay Correlation factor; (2) On Board Stability (OBS) Not Updating with Manual Change for Open Channel Assays may continue to use the reagent past its expiration date leading to potential erroneous patient sample results

    • Ongoing Z-2026-2021 FDA Class II initiated 13 May 2021 on shared 510(k) K151767

    Valves used on the Atellica CH 930, Atellica IM 1300 and Atellica IM 1600 analyzers may develop a malfunction due to a manufacturing defect and may result in the valve wearing and leaking over time. The leaking is a risk in valves subject to high pressure or high wear and may impact the result accuracy of any assay.

    • Ongoing Z-1870-2021 FDA Class II initiated 4 May 2021 on shared 510(k) K151767

    Photometer Lamp May Reach Saturation Without Flagging Results, may generate erroneously elevated or depressed patient results

    • Terminated Z-0861-2021 FDA Class II initiated 2 Dec 2020 on shared 510(k) K151767

    Multiple issues in Software v1.23.2 and lower-may lead to the reporting of discrepant patient results

    • Terminated Z-1797-2020 FDA Class II initiated 27 Feb 2020 on shared 510(k) K151767

    Editing an assay Test Definition and switching to another assay s Test Definition screen without saving the changes using the save button on the screen, may corrupt the settings of the assay s test definition, and Auto-Rerun or Auto-Dilution results may generate a result of Zero (0) for quantitative assays or Negative for qualitative assays if a well of the reagent pack is not calibrated.

    • Terminated Z-0862-2020 FDA Class II initiated 11 Oct 2019 on shared 510(k) K151767

    On the Atellica CH 930 Analyzer, when scanning barcodes at the module console for Integrated Multisensor Technology (IMT) system fluids (Standard A (Std A) and Standard B (Std B)) for Sodium (Na), Potassium (K), and Chloride (Cl), the system will translate the decimal point separators to commas. This will result in invalid concentration values for the fluids, therefore the system will utilize default nominal values instead of lot specific IMT fluid concentration values for calculation of the calibrations and results for the Na, K, and Cl methods.

    • Terminated Z-0581-2020 FDA Class II initiated 23 Sep 2019 on shared 510(k) K151767

    Potential for calibration error resulting in QC failures after the calibration run with QC and patient results being 5 times higher.

    • Terminated Z-0148-2020 FDA Class II initiated 30 Jul 2019 on shared 510(k) K151767

    Atellica CH 930 Analyzer - Erroneous Indices for Hemolysis and Lipemia in Software versions 1.19.2 and below

    • Terminated Z-0782-2019 FDA Class II initiated 26 Sep 2018 on shared 510(k) K151767

    Multiple Issues Identified in Atellica Solution System Software in V 1.14.2 and lower in: Atellica IM 1300 Analyzer Atellica IM 1600 Analyzer;Atellica CH 930 Analyzer; Atellica Sample Handler Prime

    • Terminated Z-0194-2019 FDA Class II initiated 29 Jun 2018 on shared 510(k) K151767

    Atellica Solution system software (SW) version 1.13 and lower, five (5) behavioral issues were identified: 1. Reagent Lock may not work as intended with Primary Reagent ReadyPacks and Ancillary Packs when more than one (1) lot of specific Reagent kits are loaded on the analyzer at the same time. 2. Sample barcodes may be incorrectly read 3. The Atellica IM 1300 Analyzer and Atellica IM 1600 Analyzer may not run CEA dilutions at 50x and 100x. The Analyzer may post a Sample Integrity Error when 50x or 100x dilutions are ordered for Carcinoembryonic Antigen (CEA). Dilution factors lower than 50x and neat samples are not affected by this behavior. 4. The Atellica CH 930 Analyzer may continue to display the default reporting units after the reporting units have been changed. 5. The Atellica CH 930 Analyzer may not display results for sample if certain assays are configured to auto-dilute results above or below the assay measuring interval.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade Name
Atellica CH Albumin BCP (AlbP) EUDAMED
Atellica CH AlbP GUDID
Generic Name
Albumin IVD, kit, spectrophotometry
Device Name
IVDR_67_TTN_DUB-C_b_reag_albp
Model / Ref / Catalog
11645753, IVDR_67_TTN_DUB-C_B_REAG_ALBP
Primary DI / UDI-DI
00630414654003
Basic UDI-DI
0405686900760VQ
Unit of Use DI
00630414322063
510(k) Number
FDA Product Code
CJW
EMDN Code
W01010201 Albumin (cc)
GMDN Term
Albumin IVD, kit, spectrophotometry
Device Class
Class B EUDAMED
Class II GUDID
Regulation Number
862.1035
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device ClassEUDAMED
Class B
GUDID
Class II

Other devices from Siemens Healthcare Diagnostics Inc.

See all devices from Siemens Healthcare Diagnostics Inc. →

Properties

  • Reagent
  • Professional Testing
  • Lot / Batch Number
  • Expiration Date

Other properties (20)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Contains Latex: No
  • Human Tissues: No
  • Animal Tissues: No
  • Microbial Substances: No
  • Self Testing: No
  • Near-Patient Testing: No
  • Companion Diagnostics: No
  • Surgical Instrument: No
  • New Device: No
  • Prescription Use: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No
  • Manufacturing Date: No