Skip to content

Atellica CH CA_2 11097644

by Siemens Healthcare Diagnostics Inc.

Ref 11097644Model IVDR_67_TTN_DUB-C_B_REAG_CA_2

Atellica CH CA_2 11097644 is an in vitro diagnostic device (EU IVDR Class B; FDA Class II; FDA product code CJY, Azo Dye, Calcium) made by Siemens Healthcare Diagnostics Inc., registered in EUDAMED on 21 May 2026 (Basic UDI-DI 0405686900772VX), cleared under FDA 510(k) K083386 on 2 Apr 2009 and listed in FDA GUDID since 24 Sep 2018 (UDI-DI 00630414220697), active as of 23 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE IVDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K083386

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDR EUDAMED Number0405686900772VX Basic UDI-DI 00630414220697UDI-DIDate21 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00630414220697 UDI-DI Date24 Sep 2018ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK083386 Date2 Apr 2009DecidedStatusActive

Official records

From the FDA record

Device description
Calcium_2 (CA_2) Atellica CH - RGT 8200T
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0405686900772VX registered 21 May 2026 Active
  • FDA 510(k) K083386 decided 2 Apr 2009 Active
  • FDA GUDID UDI-DI 00630414220697 listed 24 Sep 2018 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-0928-2022 FDA Class II initiated 9 Feb 2022

    Siemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting quality control (QC), patient samples, and calibrator results.

Timeline

4 dated events

  1. Cleared FDA 510(k) K083386
  2. Listed FDA GUDID 00630414220697
  3. Recall initiated FDA recalls Z-0928-2022
  4. Registered EUDAMED 0405686900772VX

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Atellica CH Calcium_2 (CA_2) EUDAMED
Atellica CH CA_2 GUDID
Generic name
Calcium (Ca2+) IVD, kit, spectrophotometry
Device name
IVDR_67_TTN_DUB-C_B_REAG_CA_2
Model / Ref / Catalog
11097644, IVDR_67_TTN_DUB-C_B_REAG_CA_2
Primary DI / UDI-DI
00630414220697
Basic UDI-DI
0405686900772VX
Unit of use DI
00630414246413
510(k) Number
FDA product code
CJY
EMDN code
W01010303 Calcium
GMDN term
Calcium (Ca2+) IVD, kit, spectrophotometry
Device class
Class B EUDAMED
Class II GUDID
Regulation number
862.1145
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class B
GUDID
Class II

Device class is stated on each registry's own scale: Class B in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under CALCIUM.

Other devices from Siemens Healthcare Diagnostics Inc.

See all devices from Siemens Healthcare Diagnostics Inc. →

Properties

  • Reagent
  • Professional testing
  • Lot / batch number
  • Expiration date
Other properties (22, all answered No)