Skip to content

Atellica CH IP 11097611

by Siemens Healthcare Diagnostics Inc.

Ref 11097611Model IVDR_67_TTN_DUB-C_B_REAG_IP_c

Atellica CH IP 11097611 is an in vitro diagnostic device (EU IVDR Class B; FDA Class I; FDA product code CEO, Phosphomolybdate (colorimetric), inorganic phosphorus) made by Siemens Healthcare Diagnostics Inc., registered in EUDAMED on 22 May 2026 (Basic UDI-DI 0405686901733VU), cleared under FDA 510(k) K991576 on 30 Jun 1999 and listed in FDA GUDID since 24 Sep 2020 (UDI-DI 00630414596303), active as of 24 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE IVDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

Recall on shared 510(k) K991576; other models may be affected

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K991576

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDR EUDAMED Number0405686901733VU Basic UDI-DI 00630414596303UDI-DIDate22 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00630414596303 UDI-DI Date24 Sep 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK991576 Date30 Jun 1999DecidedStatusActive

Official records

From the FDA record

Device description
Phosphorus (IP) Atellica CH - RGT 5100T
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0405686901733VU registered 22 May 2026 Active
  • FDA 510(k) K991576 decided 30 Jun 1999 Active
  • FDA GUDID UDI-DI 00630414596303 listed 24 Sep 2020 Listed

Recalls

3 recalls · 1 ongoing · FDA

    • Ongoing Z-1498-2022 FDA Class II initiated 28 Jun 2022 on shared 510(k) K991576

    Falsely Elevated Atellica CH Microalbumin_2 (ALB_2) Results due to Reagent Carryover from the Iron_2 Assay. This defect occurs only when a microalbumin test is run immediately after an iron test.

    • Terminated Z-2062-2018 FDA Class II initiated 27 Mar 2018 on shared 510(k) K991576

    Urea Nitrogen reagent kit demonstrated an increased incidence of Calibration Failures. Results cannot be generated by the system when calibration fails.

    • Terminated Z-1658-2016 FDA Class II initiated 17 Mar 2016 on shared 510(k) K991576

    Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyrone) interference with Trinder and Trinder-like reaction assays. Siemens has confirmed that falsely depressed results may occur on samples drawn from patients receiving N-Acetylcysteine (NAC) or Metamizole. NAC is the accepted antidote for acetaminophen toxicity and is justified in patients at signific

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

6 dated events

  1. Cleared FDA 510(k) K991576
  2. Recall initiated FDA recalls Z-1658-2016
  3. Recall initiated FDA recalls Z-2062-2018
  4. Listed FDA GUDID 00630414596303
  5. Recall initiated FDA recalls Z-1498-2022
  6. Registered EUDAMED 0405686901733VU

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Atellica CH Inorganic Phosphorus (IP) EUDAMED
Atellica CH IP GUDID
Generic name
Inorganic phosphate (PO43-) IVD, kit, spectrophotometry
Device name
IVDR_67_TTN_DUB-C_B_REAG_IP_c
Model / Ref / Catalog
11097611, IVDR_67_TTN_DUB-C_B_REAG_IP_c
Primary DI / UDI-DI
00630414596303
Basic UDI-DI
0405686901733VU
510(k) Number
FDA product code
CEO
EMDN code
W01010307 Phosphate inorganic / phosphorus
GMDN term
Inorganic phosphate (PO43-) IVD, kit, spectrophotometry
Device class
Class B EUDAMED
Class I GUDID
Regulation number
862.1580
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class B
GUDID
Class I

Device class is stated on each registry's own scale: Class B in the EU (EUDAMED), Class I in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under PHOSPHATE INORGANIC / PHOSPHORUS.

Other devices from Siemens Healthcare Diagnostics Inc.

See all devices from Siemens Healthcare Diagnostics Inc. →

Properties

  • Reagent
  • Professional testing
  • Lot / batch number
  • Expiration date
Other properties (22, all answered No)