Atellica® CI Analyzer, Atellica® IMThyroid Stimulating Hormone 3-Ultra (TSH3-UL), Atellica® CH Albumin BCP (AlbP)
by Siemens Healthcare Diagnostics, Inc.
510(k) K222116Ref 11097530Model IVDR_67_TTN_DUB-C_B_REAG_ALBP
Active
Valid until
Not listed
FDA recalls
6 ongoingTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/IVDR EUDAMED | Number0405686900760VQ 00630414595825 | Date15 Jul 2026 | StatusActive |
| United States | FDA 510(k)SESE 510(k) | NumberK222116 | Date13 Jul 2023 | StatusActive |
| United States | GUDID listing GUDID | Number00630414595825 | Date22 Dec 2017 | StatusListed |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
-
- Ongoing Z-2027-2025
Contamination of the diluent by sodium hypochlorite (NaOCl) which may impact calibrator, quality control (QC), and patient results for all assays except for sodium, potassium, and chloride.
-
- Ongoing Z-0597-2025
Potential that the IMT Diluent volume remaining (% remaining) does not decrease as expected on the Atellica CI Analyzer, potentially leading to the IMT Diluent being empty while still displaying that volume is remaining. In this case Sodium (Na), Potassium (K) and Chloride (Cl) test results may be falsely elevated. Quality Control materials demonstrate the same behavior.
-
- Ongoing Z-1003-2024
Potential for a negative bias with quality control (QC) and patient sample results when using the Atellica CH Immunoglobulin M_2 (IgM_2) reagent.
-
- Ongoing Z-0449-2022
(1)Software (SW) versions V1.25.1 and lower may result in TDef (Test Definition) Parameters for Open Channel Assays reverting to Default Value would shift test results by the magnitude of the implemented Assay Correlation factor; (2) On Board Stability (OBS) Not Updating with Manual Change for Open Channel Assays may continue to use the reagent past its expiration date leading to potential erroneous patient sample results
-
- Ongoing Z-2026-2021
Valves used on the Atellica CH 930, Atellica IM 1300 and Atellica IM 1600 analyzers may develop a malfunction due to a manufacturing defect and may result in the valve wearing and leaking over time. The leaking is a risk in valves subject to high pressure or high wear and may impact the result accuracy of any assay.
-
- Ongoing Z-1870-2021
Photometer Lamp May Reach Saturation Without Flagging Results, may generate erroneously elevated or depressed patient results
-
- Terminated Z-0861-2021
Multiple issues in Software v1.23.2 and lower-may lead to the reporting of discrepant patient results
-
- Terminated Z-1797-2020
Editing an assay Test Definition and switching to another assay s Test Definition screen without saving the changes using the save button on the screen, may corrupt the settings of the assay s test definition, and Auto-Rerun or Auto-Dilution results may generate a result of Zero (0) for quantitative assays or Negative for qualitative assays if a well of the reagent pack is not calibrated.
-
- Terminated Z-0862-2020
On the Atellica CH 930 Analyzer, when scanning barcodes at the module console for Integrated Multisensor Technology (IMT) system fluids (Standard A (Std A) and Standard B (Std B)) for Sodium (Na), Potassium (K), and Chloride (Cl), the system will translate the decimal point separators to commas. This will result in invalid concentration values for the fluids, therefore the system will utilize default nominal values instead of lot specific IMT fluid concentration values for calculation of the calibrations and results for the Na, K, and Cl methods.
-
- Terminated Z-0581-2020
Potential for calibration error resulting in QC failures after the calibration run with QC and patient results being 5 times higher.
-
- Terminated Z-0148-2020
Atellica CH 930 Analyzer - Erroneous Indices for Hemolysis and Lipemia in Software versions 1.19.2 and below
-
- Terminated Z-0782-2019
Multiple Issues Identified in Atellica Solution System Software in V 1.14.2 and lower in: Atellica IM 1300 Analyzer Atellica IM 1600 Analyzer;Atellica CH 930 Analyzer; Atellica Sample Handler Prime
-
- Terminated Z-0194-2019
Atellica Solution system software (SW) version 1.13 and lower, five (5) behavioral issues were identified: 1. Reagent Lock may not work as intended with Primary Reagent ReadyPacks and Ancillary Packs when more than one (1) lot of specific Reagent kits are loaded on the analyzer at the same time. 2. Sample barcodes may be incorrectly read 3. The Atellica IM 1300 Analyzer and Atellica IM 1600 Analyzer may not run CEA dilutions at 50x and 100x. The Analyzer may post a Sample Integrity Error when 50x or 100x dilutions are ordered for Carcinoembryonic Antigen (CEA). Dilution factors lower than 50x and neat samples are not affected by this behavior. 4. The Atellica CH 930 Analyzer may continue to display the default reporting units after the reporting units have been changed. 5. The Atellica CH 930 Analyzer may not display results for sample if certain assays are configured to auto-dilute results above or below the assay measuring interval.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- Atellica CH Albumin BCP (AlbP) EUDAMEDAtellica CH AlbP GUDID
- Generic Name
- Albumin IVD, kit, spectrophotometry
- Device Name
- IVDR_67_TTN_DUB-C_b_reag_albp
- Model / Ref / Catalog
- 11097530, IVDR_67_TTN_DUB-C_B_REAG_ALBP
- Primary DI / UDI-DI
- 00630414595825
- Basic UDI-DI
- 0405686900760VQ
- Unit of Use DI
- 00630414006871
- FDA Product Code
- JLW 510(k)CJW GUDID
- EMDN Code
- W01010201 Albumin (cc)
- GMDN Term
- Albumin IVD, kit, spectrophotometry
- Device Class
- Class B EUDAMEDClass II 510(k)GUDID
- Regulation
- 21 CFR Part 862.1690 510(k)862.1035 GUDID
- EU market of registration
- Germany
- Advisory Committee
- Clinical Chemistry
- FDA Decision
- SESE Substantially Equivalent
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | 510(k) | GUDID |
|---|---|---|---|
| 510(k) Number | — | K222116 | K151767 |
| FDA Product Code | — | JLW | CJW |
| Device Class | Class B | Class II | Class II |
| Regulation Number | — | 862.1690 | 862.1035 |
Overview
AI-generated summary, 18 Sep 2026
The Atellica CI Analyzer, Atellica IM Thyroid Stimulating Hormone 3-Ultra (TSH3-UL), and Atellica CH Albumin BCP (AlbP) are in vitro diagnostic devices designed for quantitative immunoassay measurements. The TSH3-UL assay determines thyroid-stimulating hormone levels in human serum and plasma (EDTA or lithium heparin), while the AlbP assay quantifies albumin in human serum and plasma (lithium heparin or potassium EDTA). Both assays operate on the Atellica CI Analyzer platform, a clinical chemistry analyzer.
These assays are intended for use in clinical chemistry laboratories and are supplied as single-use reagents for automated analysis on the Atellica CI Analyzer. The devices are authorized under FDA 510(k) clearance and comply with the In Vitro Diagnostic Regulation (IVDR). The TSH3-UL and AlbP assays are configured for in vitro diagnostic use, with no specific MRI safety or sterility requirements stated beyond standard laboratory practices. The analyzer supports multiple assay types, including those listed in the provided registration numbers.
Other devices from Siemens Healthcare Diagnostics
Properties
Other properties (20)
- Sterile: No
- Single Use: No
- Implantable: No
- Contains Latex: No
- Human Tissues: No
- Animal Tissues: No
- Microbial Substances: No
- Self Testing: No
- Near-Patient Testing: No
- Companion Diagnostics: No
- Surgical Instrument: No
- New Device: No
- Prescription Use: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No
- Manufacturing Date: No