Atellica SH Prime

by Siemens Healthcare Diagnostics Inc.

Ref 11781419Model IVDR_67_TTN_DUB-C_A_INST_Prime

Active European Union. Also listed in GUDID (US).

CE IVDR

Valid until

Not listed

EUDAMED holds no validity date

FDA recalls

2 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, GUDID, synced 24 Oct 2026. What this means

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDR EUDAMED Number0405686902027V5 Basic UDI-DIDate3 Aug 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00630414660790 UDI-DIDate30 Jun 2026ListedStatusListed GUDID: in commercial distribution

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

8 recalls · 2 ongoing · FDA

    • Ongoing Z-0496-2025 FDA Class II initiated 21 Oct 2024

    A manufacturing defect causes Atellica CH Reaction Ring Cuvette Segments with lot numbers N15 on the packaging or 15 on the underside of the cuvette segment have a potential for imprecision and erroneously depressed or elevated QC and patient results for seven (7) analytes: Ammonia, Acetaminophen, Alanine Aminotransferase (ALT), Hemoglobin A1c, Creatinine Kinase (CK), Cystatin C, and Salicylate.

    • Ongoing Z-1421-2020 FDA Class II initiated 12 Jan 2020 on shared 510(k) K161954

    Some lots ending in "17", "18", "19", or higher may have cuvette defects allowing water from the water bath to contaminate the interior of the cuvette, which may falsely elevate or depress sample results.

    • Terminated Z-1301-2019 FDA Class II initiated 7 Mar 2019 on shared 510(k) K161954

    There were multiple issues identified in the system software which required an update.

    • Terminated Z-0783-2019 FDA Class II initiated 26 Sep 2018 on shared 510(k) K161954

    Multiple Issues Identified in Atellica Solution System Software in V 1.14.2 and lower in: Atellica IM 1300 Analyzer Atellica IM 1600 Analyzer;Atellica CH 930 Analyzer; Atellica Sample Handler Prime

  • 3 recalls, same reason

    • Terminated Z-0190-2019 FDA Class II initiated 29 Jun 2018
    • Terminated Z-0189-2019 FDA Class II initiated 29 Jun 2018
    • Terminated Z-0191-2019 FDA Class II initiated 29 Jun 2018

    Atellica Solution system software (SW) version 1.13 and lower, five (5) behavioral issues were identified: 1. Reagent Lock may not work as intended with Primary Reagent ReadyPacks and Ancillary Packs when more than one (1) lot of specific Reagent kits are loaded on the analyzer at the same time. 2. Sample barcodes may be incorrectly read 3. The Atellica IM 1300 Analyzer and Atellica IM 1600 Analyzer may not run CEA dilutions at 50x and 100x. The Analyzer may post a Sample Integrity Error when 50x or 100x dilutions are ordered for Carcinoembryonic Antigen (CEA). Dilution factors lower than 50x and neat samples are not affected by this behavior. 4. The Atellica CH 930 Analyzer may continue to display the default reporting units after the reporting units have been changed. 5. The Atellica CH 930 Analyzer may not display results for sample if certain assays are configured to auto-dilute results above or below the assay measuring interval.

    • Terminated Z-1587-2018 FDA Class II initiated 26 Feb 2018 on shared 510(k) K161954

    When more than one immunoassay analyzer is connected to a single solution system, reporting and conversion factors may not be applied to all analyzers

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Generic Name
Specimen processing instrument IVD
Device Name
IVDR_67_TTN_DUB-C_A_INST_Prime
Model / Ref / Catalog
IVDR_67_TTN_DUB-C_A_INST_Prime, 11781419
Primary DI / UDI-DI
00630414660790
Basic UDI-DI
0405686902027V5
510(k) Number
FDA Product Code
JJE
EMDN Code
W0201010180 Chemistry analysers - hardware accessories
GMDN Term
Specimen processing instrument IVD
Device Class
Class A EUDAMED
Class I GUDID
Regulation Number
862.2160
Market of Registration
Belgium
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device ClassEUDAMED
Class A
GUDID
Class I

Manufacturer details

EUDAMED SRN
US-MF-000016560
Authorised representative
Siemens Healthcare Diagnostics Manufacturing Limited IE-AR-000006763

Other devices from Siemens Healthcare Diagnostics Inc.

See all devices from Siemens Healthcare Diagnostics Inc. →

Properties

  • Professional Testing
  • Surgical Instrument
  • Serial Number

Other properties (21)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Contains Latex: No
  • Human Tissues: No
  • Animal Tissues: No
  • Microbial Substances: No
  • Reagent: No
  • Self Testing: No
  • Near-Patient Testing: No
  • Companion Diagnostics: No
  • New Device: No
  • Prescription Use: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Lot / Batch Number: No
  • Expiration Date: No
  • Manufacturing Date: No