# Audiotraveller Model AA222

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/audiotraveller-model-aa222-ety>
- Manufacturer: [Interacoustics A/S, Assens](https://devicerts.com/manufacturers/interacoustics-a-s) (FDA registration: Denmark)
- Name in the registry: AUDIOTRAVELLER, MODEL AA222
- Device class: Class II (US FDA)
- FDA product code: ETY

## Overview

*AI-generated summary, 2026-09-19. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Audiotraveller Model AA222 is an Audiometer, Tympanometer (ETY classification) designed for measuring auditory function and middle ear impedance. It performs tympanometry at 226 Hz (upgradeable to 1000 Hz), audiometry, and the Stenger test to assess hearing thresholds and middle ear status.

This device is intended for use in clinical settings such as hospitals, ENT clinics, and audiology offices by trained operators. Supplied as a reusable electronic instrument, it requires no sterility processing and is not MRI-compatible. Authorized under FDA 510(k) clearance (K022728), it operates within Class II regulatory standards for auditory testing.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K022728 · decision 2002-10-11 · decision SESE · status: Active

## Recalls

No recall on record.

## Identifiers

- 510(k) Number: K022728 [FDA 510(k)]
- FDA product code: ETY [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 874.1090 [FDA 510(k)]
- Advisory committee: Ear, Nose, Throat [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Audiotraveller Model AA222, Interacoustics A/S, Assens. deviCERTS medical device catalogue. https://devicerts.com/devices/audiotraveller-model-aa222-ety (data as of 2026-11-28).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-28
- JSON: <https://devicerts.com/devices/audiotraveller-model-aa222-ety.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/audiotraveller-model-aa222-ety
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.