Aurora EV-ICD System
PMA P220012
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA PMAAPPR | NumberP220012 | Date20 Oct 2023 | StatusActive |
Recalls
-
- Ongoing Z-0726-2026
There is a potential for delayed time to high-voltage (HV) therapy should a rare sequence of events occur.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Full name
- Aurora EV-ICD
- Trade name
- Aurora EV-ICD System
- Generic name
- Implantable cardioverter defibrillator (non-CRT)
- PMA number
- FDA product code
- LWS
- Device class
- Class III
- Advisory committee
- Cardiovascular
- FDA decision
- APPR Approved
Overview
AI-generated summary, 18 Sep 2026
The Aurora EV-ICD System is an implantable cardioverter defibrillator (non-CRT) designed for the automated treatment of patients who have experienced, or are at significant risk of developing, life-threatening ventricular tachyarrhythmias. It provides essential cardiac therapies including antitachycardia pacing, cardioversion, and defibrillation to help prevent sudden cardiac death in patients with conditions such as coronary disease, cardiomyopathy, or inherited arrhythmia syndromes.
This system utilizes the Epsila EV MRI SureScan Model EV2401 extravascular lead, which is indicated for placement in the anterior mediastinum. Implantation is supported by the Epsila EV EAZ101 Sternal Tunneling Tool and the Epsila EV EAZ201 Transverse Tunneling Tool. The device has received FDA PMA authorization for clinical use in managing patients at risk of life-threatening arrhythmias.
Other devices from Medtronic, Inc.
Questions
AI-generated answers, 18 Sep 2026
What is the primary function of the Aurora EV-ICD System?
The system is designed to provide automated treatment for life-threatening ventricular tachyarrhythmias through the delivery of antitachycardia pacing, cardioversion, and defibrillation therapies.
Which patients may be indicated for this device?
The device is indicated for patients at risk of sudden cardiac death due to conditions such as previous ventricular tachyarrhythmias, coronary disease with left ventricular dysfunction, cardiomyopathy, inherited primary arrhythmia syndromes, or congenital heart disease.
What components are used during the implantation of the lead?
The system uses the Epsila EV MRI SureScan Model EV2401 lead, which is implanted using the Epsila EV EAZ101 Sternal Tunneling Tool and the Epsila EV EAZ201 Transverse Tunneling Tool.