Skip to content

AUTION™ Staining Solution BAC 73810

by Arkray USA, Inc.

AUTION Staining Solution BAC 73810 is an urine analyser IVD (FDA Class I; FDA product code KQO, Automated Urinalysis System) made by Arkray USA, Inc., cleared under FDA 510(k) K121456 on 1 Feb 2013 and listed in FDA GUDID since 23 Sep 2016 (UDI-DI 04987486738107), active as of 22 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K121456

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number04987486738107 UDI-DI Date23 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK121456 Date1 Feb 2013DecidedStatusActive

Official records

From the FDA record

Device description
Consumable for the identification and enumeration of WBC, RBC, Casts, Epithelial Cells, and Bacteria as well as flags for pathologic casts, yeast, crystal, small round cells, mucus, and sperm in urine sediment.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K121456 decided 1 Feb 2013 Active
  • FDA GUDID UDI-DI 04987486738107 listed 23 Sep 2016 Listed

Recalls

1 recall · FDA

    • Terminated Z-1850-2019 FDA Class II initiated 3 May 2019

    This correction is being initiated due to a software issue which results in the possibility of incorrect patient information being assigned to sample results when the following rare combination of three specific events were to occur: 1) No measurement results are generated due to an error by a urine sediment measurement. 2) The instrument is shutdown incorrectly. 3) An item rack is used for subsequent sample measurements.

Timeline

3 dated events

  1. Cleared FDA 510(k) K121456
  2. Listed FDA GUDID 04987486738107
  3. Recall initiated FDA recalls Z-1850-2019

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
AUTION™ Staining Solution BAC
Generic name
Urine analyser IVD, laboratory
Model / reference
73810
Primary DI / UDI-DI
04987486738107
510(k) Number
FDA product code
KQO
GMDN term
Urine analyser IVD, laboratory
Device class
Class I
Regulation number
862.2900
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Urine analyser IVD, laboratory.

Other devices from Arkray USA, Inc.

See all devices from Arkray USA, Inc. →

Properties

  • Lot / batch number
  • Expiration date
Other properties (13, all answered No)