Avi Model 4225 Vented Piggyback IV Admin Set

by 3M Avi, Inc.

510(k) K912069

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK912069 Date14 Oct 1993ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
FPA
Device Class
Class II
Regulation
21 CFR Part 880.5440
Advisory Committee
General Hospital
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The AVI Model 4225 Vented Piggyback IV Administration Set is a vented piggyback intravenous administration set designed for secondary fluid infusion. It facilitates the controlled delivery of medications or solutions into a primary IV line, allowing simultaneous administration of multiple fluids without cross-contamination. The vented design prevents pressure buildup, ensuring stable flow rates and reducing the risk of air embolism. This device is classified under product code FPA and is intended for use in general hospital settings.

This IV administration set is supplied as a single-use, non-sterile device (unless terminally sterilized per manufacturer specifications) and is intended for one-time clinical use. It features an 83-inch length and a priming volume of 17 mL, with a drip chamber calibrated at 10 drops per mL. The device has received FDA 510(k) clearance (K912069) under a traditional review pathway, with a decision of Substantially Equivalent to the predicate device. Storage should follow manufacturer guidelines to maintain integrity, and compatibility with MRI environments is not specified.

Other devices from 3M Avi, Inc.

See all devices from 3M Avi, Inc. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the AVI Model 4225 Vented Piggyback IV Administration Set used for?

    This device is designed for secondary fluid infusion in a primary IV line, allowing simultaneous administration of medications or solutions without cross-contamination. The vented design ensures stable flow rates by preventing pressure buildup, which also reduces the risk of air embolism—a critical safety feature for hospital patients requiring multiple infusions.

  • Is the AVI 4225 supplied sterile, and how is it intended for use?

    The AVI Model 4225 is supplied as a single-use device, but its sterility depends on terminal sterilization per manufacturer specifications. It is explicitly intended for one-time clinical use only, ensuring patient safety and preventing contamination from reuse.

  • What are the key specifications of the AVI 4225, including length and drip chamber calibration?

    The set features an 83-inch length for flexibility in patient positioning, with a priming volume of 17 mL to minimize dead space. The drip chamber is calibrated at 10 drops per milliliter, providing precise flow control for secondary infusions. These specifications help clinicians achieve accurate medication delivery while maintaining stability.

  • How should the AVI 4225 be stored to maintain its integrity?

    Storage instructions are provided by the manufacturer to preserve the device’s integrity, though specific details (e.g., temperature, humidity, or packaging) are not included in the data. Adhering to these guidelines ensures the set remains functional and safe for its intended single-use application.

  • Does the AVI 4225 have any compatibility considerations, such as MRI environments?

    The data does not specify compatibility with MRI environments, so clinicians should verify compatibility with their facility’s MRI protocols before use. Since the device is primarily intended for general hospital settings, additional testing may be required if MRI exposure is anticipated.