# Avon 6430-0-030

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/avon-6430-0-030>
- Manufacturer: [Howmedica Osteonics Corp.](https://devicerts.com/manufacturers/howmedica-osteonics-corp) (United States)
- Device class: Class II (US FDA)
- FDA product code: KRR, HSX, NPJ, HRY
- GMDN: Polyethylene patella prosthesis (34199)

## Registrations and authorizations

- **GUDID** · GUDID listing · United States · UDI-DI 07613327049312 · listed 2015-09-24 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K052917 · decision 2005-12-27 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K051948 · decision 2005-10-21 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K020841 · decision 2002-04-11 · decision SESE · status: Active · from GUDID

## Recalls

- Z-3206-2026 · Class II · ongoing · initiated 2026-07-30: Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or disassociated device. Potential harms include revision surgery, pain, and inflammation.
- Z-0895-2024 · Class II · ongoing · initiated 2023-12-01 · matched through shared submission K051948, may concern other models: Product manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties.
- Z-0894-2024 · Class II · ongoing · initiated 2023-12-01 · matched through shared submission K051948, may concern other models: Product manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties.
- Z-0896-2024 · Class II · ongoing · initiated 2023-12-01 · matched through shared submission K051948, may concern other models: Product manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties.
- Z-0893-2024 · Class II · ongoing · initiated 2023-12-01 · matched through shared submission K051948, may concern other models: Product manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties.
- Z-0897-2024 · Class II · ongoing · initiated 2023-12-01 · matched through shared submission K051948, may concern other models: Product manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties.
- Z-0900-2024 · Class II · ongoing · initiated 2023-12-01 · matched through shared submission K051948, may concern other models: Product manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties.
- Z-0606-2012 ·  · terminated · initiated 2011-08-17: Two National Joint Registries suggest that the EIUS Unicompartmental System is associated with a higher revision rate then the unicompartmental devices.

## Identity

- Trade name: Avon [FDA GUDID (AccessGUDID)]
- Generic name: Polyethylene patella prosthesis [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: 6430-0-030 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 07613327049312 [FDA GUDID (AccessGUDID)]
- FDA product code: KRR [FDA GUDID (AccessGUDID)]; HSX [FDA GUDID (AccessGUDID)]; NPJ [FDA GUDID (AccessGUDID)]; HRY [FDA GUDID (AccessGUDID)]
- GMDN term: Polyethylene patella prosthesis (34199) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 888.3540 [FDA GUDID (AccessGUDID)]; 888.3520 [FDA GUDID (AccessGUDID)]; 888.3560 [FDA GUDID (AccessGUDID)]; 888.3530 [FDA GUDID (AccessGUDID)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- MRI safety: MR Conditional [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Implantable: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Avon 6430-0-030, Howmedica Osteonics Corp. deviCERTS medical device catalogue. https://devicerts.com/devices/avon-6430-0-030 (data as of 2026-11-18).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-23
- Statuses computed as of: 2026-11-18
- JSON: <https://devicerts.com/devices/avon-6430-0-030.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/avon-6430-0-030
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.