AxiEM™ 9733533XOM is a Class II device made by Medtronic Navigation Inc., cleared under FDA 510(k) K001284 on 12 Jun 2000 and listed in FDA GUDID since 30 Dec 2021 (UDI-DI 00763000588342), active as of 8 Nov 2026. 26 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00763000588342 | Date30 Dec 2021 | StatusListed |
| United States | FDA 510(k)SESE | NumberK001284 | Date12 Jun 2000 | StatusActive |
Official records
- AccessGUDID record 00763000588342
- FDA 510(k) database K001284
Across registries
- FDA 510(k) K001284 decided 12 Jun 2000 Active
- FDA GUDID UDI-DI 00763000588342 listed 30 Dec 2021 Listed
Recalls
-
- Terminated Z-2317-2016
- Terminated Z-2319-2016
Medtronic Navigation, Inc. announces a voluntary field action for the Medtronic Navigation StealthStation Software applications affected by Neurologica BodyTom/CereTom floor-based scanners.
-
- Terminated Z-1587-2014
- Terminated Z-1581-2014
- Terminated Z-1582-2014
- Terminated Z-1600-2014
- Terminated Z-1584-2014
- Terminated Z-1601-2014
- Terminated Z-1578-2014
- Terminated Z-1580-2014
- Terminated Z-1591-2014
- Terminated Z-1590-2014
- Terminated Z-1595-2014
- Terminated Z-1594-2014
- Terminated Z-1593-2014
- Terminated Z-1596-2014
- Terminated Z-1598-2014
- Terminated Z-1592-2014
- Terminated Z-1589-2014
- Terminated Z-1585-2014
- Terminated Z-1579-2014
- Terminated Z-1602-2014
- Terminated Z-1583-2014
- Terminated Z-1599-2014
- Terminated Z-1588-2014
- Terminated Z-1597-2014
- Terminated Z-1586-2014
Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure sterility.
-
- Terminated Z-0718-06
Knee Navigation Disposable Kits were programmed with an incorrect identification number on the tracker ROM chip which would not permit navigation during surgery.
Timeline
- Recall initiated FDA recalls Z-1579-2014
- Recall initiated FDA recalls Z-1602-2014
- Recall initiated FDA recalls Z-1583-2014
- Recall initiated FDA recalls Z-1599-2014
- Recall initiated FDA recalls Z-1588-2014
- Recall initiated FDA recalls Z-1597-2014
- Recall initiated FDA recalls Z-1586-2014
- Recall initiated FDA recalls Z-2317-2016
- Recall initiated FDA recalls Z-2319-2016
- Listed FDA GUDID 00763000588342
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- AxiEM™
- Generic name
- Stereotactic surgery system probe, single-use
- Model / reference
- 9733533XOM
- Primary DI / UDI-DI
- 00763000588342
- 510(k) Number
- FDA product code
- HAW
- GMDN term
- Stereotactic surgery system probe, single-use
- Device class
- Class II
- Regulation number
- 882.4560
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code HAW (Neurological stereotaxic Instrument).
- NEXDRIVE™ w/DIG MI-1000-00771 by FHC, INC.
- 6000-055-000 by Stryker Leibinger
- Viewpoint Tools Sterrad by Philips Medical Systems (Cleveland), Inc.
- Vectorvision FLUORO3D by Brainlab AG
- ACCELUS SNAP ON SPHERZ - 4 PACK 6004 by IZI MEDICAL PRODUCTS LLC
- Cranial Image Guided Surgery System, Navigation Software Cranial, Navigation Software ENT, Registration Software Cranial, Automatic Registration 2.0, Ultrasound Navigation Software (BK), Intraoperative Structure Update by Brainlab AG