Axiom Artis Modular Angiography System
510(k) K010721
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK010721 | Date30 Mar 2001 | StatusActive |
Recalls
-
- Terminated Z-0711-2018
The possibility exists for the wireless foot switch to fail due to impacts by external factors, such as electrostatic discharge that exceed a certain intensity. If the foot switch fails, it will no longer be able to be used to release radiation. The hand switch provided can be used to release exposures; however, fluoroscopic examinations will not be possible.
-
- Terminated Z-2393-2016
The possibility exists for contaminants, in the form of biomass, to develop in the cooling system of Artis systems resulting in damage to the pump system.
-
- Terminated Z-2342-2015
The possibility exists for a large amount of liquid to seep through the top cover of the table and penetrate the components inside the table. If this occurs, table movements may no longer be possible. No injuries reported.
-
- Terminated Z-2587-2014
There is a potential problem with the AXIOM Artis or Artis zee system in connection with the hand switch operated at the patient table which may result in uncontrolled release of an x-ray image.
-
- Terminated Z-2233-2010
The Axiom Artis MP, Artis dMP or Artis zee Multipurpose C-arm gearbox can become damaged. If the gearbox is damaged, the C-arm may tilt away when being repositioned and collide with nearby objects in its range of motion.
-
- Terminated Z-0483-2010
c-arm may tilt
-
- Terminated Z-1439-2009
Improper installation of accessory support arm, which could potentially result in the loosening of the arm over time causing it to fall.
-
- Terminated Z-0127-2009
- Terminated Z-0124-2009
- Terminated Z-0123-2009
- Terminated Z-0126-2009
- Terminated Z-0122-2009
- Terminated Z-0120-2009
- Terminated Z-0125-2009
- Terminated Z-0121-2009
- Terminated Z-0128-2009
Incorrect contour finding: Image may be calibrated to the wrong size catheter.
-
- Terminated Z-0193-2009
Patients could possibly fall off the table if not properly secured when: 1) moving them onto the patient table, 2) moving them on the patient table or 3) removing them from the patient table.
-
- Terminated Z-0579-2007
C-arm gantry could rapidly descend without command during use
-
- Terminated Z-0578-2007
C-arm gantry could rapidly descend without command during use.
-
- Terminated Z-0796-05
Live display in exam room may sporadically stop working although the display in the control room remains fully operational
-
- Terminated Z-0818-05
potential problem with the fluoroscopy switch on the power grip
-
- Terminated Z-1449-04
- Terminated Z-1450-04
Opacification Function of device may incorrectly merge images
-
- Terminated Z-1108-04
Error appears in the AUTOMAP function, Module 2, when PERISTEEPING or PERIVISION is activated simultaneously that causes system to crash.
-
- Terminated Z-0848-04
patient images misidentified
-
- Terminated Z-0347-03
Set delay time for contrast injection exceeds 10 seconds, radiation release button is blocked.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- IZI
- Device Class
- Class II
- Regulation
- 21 CFR Part 892.1600
- Advisory Committee
- Radiology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 28 Sep 2026
The AXIOM ARTIS MODULAR ANGIOGRAPHY SYSTEM is a system, X-ray, angiographic device intended for diagnostic imaging. It is classified as a Class II medical device under FDA regulation number 892.1600 and product code IZI.
The system received FDA 510(k) clearance (K010721) on March 30, 2001, following a traditional review process. It was found substantially equivalent to a predicate device and is manufactured by Siemens Medical Corp. The device is used in radiology settings and is not described as sterile, single-use, or MRI-safe in the provided data.
Other devices from Siemens Medical Corp.
Questions
AI-generated answers, 28 Sep 2026
What is the AXIOM ARTIS MODULAR ANGIOGRAPHY SYSTEM used for?
The AXIOM ARTIS MODULAR ANGIOGRAPHY SYSTEM is intended for diagnostic imaging as an X-ray angiographic device, used in radiology settings to visualize blood vessels and support clinical diagnosis.
Is the AXIOM ARTIS MODULAR ANGIOGRAPHY SYSTEM sterile or single-use?
The device is not described as sterile or single-use in the provided data; it is a reusable system designed for repeated use in radiology departments after appropriate cleaning and maintenance between procedures.
What regulatory pathway was used for the AXIOM ARTIS MODULAR ANGIOGRAPHY SYSTEM?
The system received FDA 510(k) clearance through a traditional review process, with clearance granted on March 30, 2001, under K010721, based on a finding of substantial equivalence to a predicate device.