Skip to content

Axis Plate 148-20001

by Extremity Medical, LLC

Axis Plate 148-20001 is an orthopaedic fixation plate (FDA Class II; FDA product code HRS, Plate, Fixation, Bone) made by Extremity Medical, LLC, cleared under FDA 510(k) K192592 on 21 Nov 2019 and listed in FDA GUDID since 27 Oct 2020 (UDI-DI 00842078117286), active as of 22 Oct 2026.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

510(k) K192592

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00842078117286 UDI-DI Date27 Oct 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK192592 Date21 Nov 2019DecidedStatusActive

Official records

From the FDA record

Device description
Plantarmedial Plate w/ Talar Wrap, Left
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K192592 decided 21 Nov 2019 Active
  • FDA GUDID UDI-DI 00842078117286 listed 27 Oct 2020 Listed

Timeline

2 dated events

  1. Cleared FDA 510(k) K192592
  2. Listed FDA GUDID 00842078117286

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Axis Plate
Generic name
Orthopaedic fixation plate, non-bioabsorbable, non-sterile
Model / reference
148-20001
Primary DI / UDI-DI
00842078117286
510(k) Number
FDA product code
HRS
GMDN term
Orthopaedic fixation plate, non-bioabsorbable, non-sterile
Device class
Class II
Regulation number
888.3030
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Similar devices in this category

Other devices filed under Orthopaedic fixation plate, non-bioabsorbable, non-sterile.

Other devices from Extremity Medical, LLC

See all devices from Extremity Medical, LLC →

Properties

  • Sterilise before use
  • Single use
  • Prescription use
  • Lot / batch number
Other properties (11, all answered No)