Skip to content

B-Clone HCG Assay

by Monoclonal Antibodies, Inc. 510(k)

Active United States

510(k) K831155

Regulatory status

as of 28 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK831155 Date2 Jun 1983ClearedStatusActive

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 6 Oct 2026.

Specification

510(k)

510(k) Number
FDA Product Code
JHJ
Device Class
Class II
Regulation
21 CFR Part 862.1155
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The B-Clone HCG Assay is an agglutination method for detecting human chorionic gonadotropin (hCG), a hormone used as a biomarker for pregnancy. This in vitro diagnostic device relies on monoclonal antibodies to identify hCG in human samples, facilitating qualitative testing for pregnancy confirmation or monitoring.

This assay is supplied as a single-use diagnostic reagent and is intended for use in clinical chemistry laboratories. It is classified under 21 CFR 862.1155 and holds an FDA 510(k) clearance (K831155) as substantially equivalent to a predicate device. No specific sterility or MRI safety requirements are noted in the regulatory data, and storage conditions are not detailed beyond standard laboratory practices.

Other devices from Monoclonal Antibodies, Inc.

See all devices from Monoclonal Antibodies, Inc. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical specialty is this device primarily intended for, and how does it function in that setting?

    The B-Clone HCG Assay is designed for use in clinical chemistry laboratories, where it serves as a qualitative diagnostic tool for detecting human chorionic gonadotropin (hCG) in human samples. It employs an agglutination method with monoclonal antibodies to identify hCG, a biomarker used to confirm pregnancy or monitor related conditions. This makes it particularly relevant for obstetrics, fertility clinics, or any setting where pregnancy testing is performed.

  • Is this device single-use, and if so, what does that mean for workflow and sample handling?

    Yes, the B-Clone HCG Assay is supplied as a single-use diagnostic reagent, meaning each test kit is intended for one use only. This design ensures consistency and reliability in results while minimizing cross-contamination risks. Clinicians should prepare a new test for each sample, adhering to standard laboratory practices for in vitro diagnostics to avoid carryover or degradation of reagents.

  • What regulatory pathway was followed for this device’s clearance, and what does that mean for its safety and equivalence?

    The B-Clone HCG Assay received FDA 510(k) clearance (K831155) under the Traditional 510(k) pathway, demonstrating it is *substantially equivalent* to a predicate device already on the market. This means the FDA reviewed its design, performance, and safety data to confirm it meets the same intended use and risk profile as the predecessor, ensuring comparable diagnostic accuracy and reliability for detecting hCG in clinical settings.

  • Are there specific storage requirements mentioned for this assay, or should it follow general lab practices?

    The regulatory data does not specify unique storage conditions beyond standard laboratory practices for in vitro diagnostics. As a single-use reagent, it should be stored in a way that maintains its integrity—typically at room temperature or as indicated on the packaging—until use. Clinicians should follow the manufacturer’s instructions (if provided) or local protocols to ensure optimal performance and shelf life.