Balloon Catheter
by Shanghai Kinetic Medical Co., Ltd. 3 variants
Ref FG1001-15Model FG1001-10, FG1001-15, FG1001-20, FG1101-10,FG1101-15, FG1101-20, FG1010, FG1015, FG1020, FG1025, FG1030, FA1010, FA1015, FA1020, FA1025, FA1030, SS101-2010, SS101-2015, SS101-2020, KMC-003-10, KMC-003-15, KMC-003-20, KMC-004-10, KMC-004-15, KMC-004-20
Balloon Catheter (FG1001-15) is an inflatable bone tamp (EU MDR Class IIa; FDA Class II) made by Shanghai Kinetic Medical Co., Ltd., registered in EUDAMED on 7 Mar 2025 (Basic UDI-DI 69386955BIK3), cleared under FDA 510(k) K113742 on 17 Sep 2012 and listed in FDA GUDID since 26 May 2016 (UDI-DI 06938695510150), active as of 22 Oct 2026.
Active
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number69386955BIK3 06938695510150 | Date7 Mar 2025 | StatusActive |
| United States | GUDID listing GUDID | Number06938695510150 | Date26 May 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK113742 | Date17 Sep 2012 | StatusActive |
Official records
- EUDAMED public site 69386955BIK3
- AccessGUDID record 06938695510150
- FDA 510(k) database K113742
From the FDA record
- Device description
- KMC Kyphoplasty System consists of four components: Balloon Catheter Tool Kit Puncture Needle KMC Medical Balloon Catheter Syringe Pump
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI 69386955BIK3 registered 7 Mar 2025 Active
- FDA 510(k) K113742 decided 17 Sep 2012 Active
- FDA GUDID UDI-DI 06938695510150 listed 26 May 2016 Listed
Timeline
- Cleared FDA 510(k) K113742
- Listed FDA GUDID 06938695510150
- Registered EUDAMED 69386955BIK3
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Inflatable bone tamp
- Model / Ref / Catalog
- FG1001-10, FG1001-15, FG1001-20, FG1101-10, FG1101-15, FG1101-20, FG1010, FG1015, FG1020, FG1025, FG1030, FA1010, FA1015, FA1020, FA1025, FA1030, SS101-2010, SS101-2015, SS101-2020, KMC-003-10, KMC-003-15, KMC-003-20, KMC-004-10, KMC-004-15, KMC-004-20
- Primary DI / UDI-DI
- 06938695510150
- Basic UDI-DI
- 69386955BIK3
- Direct marketing DI
- 06938695510150
- 510(k) Number
- FDA product code
- HRX, NDN
- EMDN code
- P099002 Orthopaedic cement preparation and application devices and kits
- GMDN term
- Inflatable bone tamp
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 888.1100, 888.3027
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Size
- Length — 15 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
| Sterilise before use | Yes | No |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 06938695510150: EUDAMED states Yes, FDA GUDID states No.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Manufacturer details
- EUDAMED SRN
- CN-MF-000017688
- Authorised representative
- Prolinx GmbH DE-AR-000005129
Similar devices in this category
Other devices filed under ORTHOPAEDIC CEMENT PREPARATION AND APPLICATION DEVICES AND KITS.
- SmartMix™ Cemvac Dual Vacuum Foot pump 3210026 by Summit Medical Ltd
- OSTEOGUN VCF-1020 by TEKNIMED
- V-HP Gun 900165 by G-21 S.R.L.
- High Viscosity Injection System T060421 by TEKNIMED
- Pro Nozzle short with knee pressurizer 66057202 by Heraeus Medical LLC
- EASYMIX SHAKER 02-0320 by Tecres S.p.A.
- MiniMix™ LV SMLV by Summit Medical Ltd
- PicoMix V 900129 by G-21 S.R.L.
- Osteon SCRW-OBCS4570 by Bonegraft Biomaterials Co.
- MixEvac 0206015000 0206-015-000 by Stryker Corp.