Skip to content

basixCOMPAK™ 00884450638521

by Merit Medical Systems, Inc.

Ref IN4918/AModel Merit Inflation Devices

basixCOMPAK 00884450638521 (IN4918/A) is a catheter/overtube balloon inflator (EU MDD Class IIa; FDA Class II; FDA product code PTM, Syringe, Balloon Inflation, Exempt) made by Merit Medical Systems, Inc., registered in EUDAMED on 6 Nov 2026 (Basic UDI-DI B-00884450638521) and listed in FDA GUDID since 11 Jun 2022 (UDI-DI 00884450638521), active as of 7 Nov 2026. 2 FDA recalls are linked to it.

Active European Union. Also listed in GUDID (US).

CE MDD

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

2 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00884450638521 Basic UDI-DI 00884450638521UDI-DIDate6 Nov 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00884450638521 UDI-DI Date11 Jun 2022ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI B-00884450638521 registered 6 Nov 2026 Active
  • FDA GUDID UDI-DI 00884450638521 listed 11 Jun 2022 Listed

Recalls

2 recalls · 2 ongoing · FDA

    • Ongoing Z-1123-2026 FDA Class II initiated 4 Dec 2025 UDI-DI 00884450638521 listed

    Inflation device handle may detach from the syringe during procedure.

    • Ongoing Z-0533-2026 FDA Class II initiated 4 Aug 2025 UDI-DI 00884450638521 listed

    Hemostasis valve has a manufacturing defect and when used the valve cap may remain depressed, leading to potential leakage, which may result in procedure inconvenience and/or hemorrhage.

Timeline

4 dated events

  1. Listed FDA GUDID 00884450638521
  2. Recall initiated FDA recalls Z-0533-2026
  3. Recall initiated FDA recalls Z-1123-2026
  4. Registered EUDAMED B-00884450638521

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
basixCOMPAK™
Generic name
Catheter/overtube balloon inflator, single-use
Device name
Merit Inflation Devices
Model / Ref / Catalog
Merit Inflation Devices, IN4918/A, 00884450638521
Primary DI / UDI-DI
00884450638521
Basic UDI-DI
B-00884450638521
FDA product code
PTM
EMDN code
Z12030302 Syringe pumps
GMDN term
Catheter/overtube balloon inflator, single-use
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
870.1650
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
Merit Inflation Devices
IN4918/A
GUDID
00884450638521
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under SYRINGE PUMPS.

Other devices from Merit Medical Systems, Inc.

See all devices from Merit Medical Systems, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Contains animal tissues or cells
  • Measuring function
  • Prescription use
  • Convenience kit
  • Premarket exempt
  • Lot / batch number
  • Expiration date
Other properties (14, all answered No)