Skip to content

BCL10-5

by Sonoscape Medical Corp. 2 variants

Ref /Model BCL10-5

BCL10-5 is a rectal ultrasound imaging system transducer (EU MDR Class IIa; FDA Class II) made by Sonoscape Medical Corp., registered in EUDAMED on 24 Sep 2023 (Basic UDI-DI 69458686P1014QT), cleared under FDA 510(k) K152165 on 26 Aug 2015 and listed in FDA GUDID since 19 Aug 2016 (UDI-DI 06945868600228), active as of 22 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K152165

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number69458686P1014QT Basic UDI-DI 06945868600228UDI-DIDate24 Sep 2023RegisteredStatusActive
United StatesGUDID listing GUDID Number06945868600228 UDI-DI Date19 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK152165 Date26 Aug 2015DecidedStatusActive

Official records

From the FDA record

Device description
BCL10-5 Ultrasonic Transducer (S9)
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 69458686P1014QT registered 24 Sep 2023 Active
  • FDA 510(k) K152165 decided 26 Aug 2015 Active
  • FDA GUDID UDI-DI 06945868600228 listed 19 Aug 2016 Listed

Recalls

2 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-2109-2014 FDA Class II initiated 9 Jul 2014 on shared 510(k) K152165
    • Terminated Z-2110-2014 FDA Class II initiated 9 Jul 2014 on shared 510(k) K152165

    The QLAB a2DQ and aCMQ features have a defect that may use incorrect measurement values under specific conditions.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Recall initiated FDA recalls Z-2109-2014
  2. Recall initiated FDA recalls Z-2110-2014
  3. Cleared FDA 510(k) K152165
  4. Listed FDA GUDID 06945868600228
  5. Registered EUDAMED 69458686P1014QT

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
BCL10-5 EUDAMED
SonoScape GUDID
Generic name
Rectal ultrasound imaging system transducer
Device name
Ultrasonic Transducer
Model / reference
BCL10-5, /
Primary DI / UDI-DI
06945868600228
Basic UDI-DI
69458686P1014QT
Direct marketing DI
06945868600228
510(k) Number
FDA product code
ITX, IYO, IYN
EMDN code
Z1104020201 Endocavitary ultrasound probes, two–dimensional
GMDN term
Rectal ultrasound imaging system transducer
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1570, 892.1560, 892.1550
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
CN-MF-000009623
Authorised representative
Shanghai International Holding Corp. GmbH(Europe) DE-AR-000000001

Similar devices in this category

Other devices filed under ENDOCAVITARY ULTRASOUND PROBES, TWO–DIMENSIONAL.

Other devices from Sonoscape Medical Corp.

See all devices from Sonoscape Medical Corp. →

Properties

  • Prescription use
  • Serial number
Other properties (23, all answered No)