BD PhaSeal Closed System Transfer Device P55
by Becton, Dickinson and Company
510(k) K130197
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK130197 | Date27 Feb 2013 | StatusActive |
Recalls
-
- Ongoing Z-2453-2025
Closed system drug transfer devices were shipped to the U.S. market without a U.S. version of the instructions for use, which could be an issue if a healthcare professional is prompted to review it.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- ONB
- Device Class
- Class II
- Regulation
- 21 CFR Part 880.5440
- Advisory Committee
- General Hospital
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The BD PhaSeal Closed System Transfer Device P55 is a Closed Antineoplastic and Hazardous Drug Reconstitution and Transfer System. It is designed to facilitate the safe handling of hazardous and antineoplastic drugs by creating an airtight, leakproof barrier that prevents environmental contamination and drug vapor escape during transfer processes.
This device is intended for single-use in clinical settings, including general hospital environments. It is classified as a Class II medical device under FDA regulations and has received Special 510(k) clearance (K130197) for use in drug reconstitution and transfer procedures. The device is not MRI-compatible and must be stored in a clean, dry environment as per manufacturer guidelines.
From the manufacturer
Why are the PhaSeal™ System and SmartSite™ VialShield devices being discontinued? After careful consideration and in alignment with the BD commitment to innovation and safety, we have made the decision to retire the original PhaSeal™ Closed System Transfer Devices (CSTD) and the SmartSite™ VialShield Vial Access Devices.
Other devices from Becton, Dickinson and Company
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the BD PhaSeal Closed System Transfer Device P55, and why is it designed for single-use only?
The BD PhaSeal Closed System Transfer Device P55 is designed to safely handle hazardous and antineoplastic drugs by creating an airtight, leakproof barrier during reconstitution and transfer processes. This prevents environmental contamination and drug vapor escape, protecting healthcare workers and patients. It is intended for single-use only because repeated use could compromise the integrity of the seal, increasing the risk of leaks, contamination, or exposure to hazardous substances. Single-use also aligns with infection control best practices in clinical settings.
How should the BD PhaSeal Closed System Transfer Device P55 be stored, and what environmental conditions are required?
The device must be stored in a clean, dry environment as specified by the manufacturer. This ensures the integrity of the components and prevents degradation from moisture or contaminants. Avoid exposure to extreme temperatures, direct sunlight, or sources of electrostatic discharge, as these could compromise the device’s functionality or sterility.
Is the BD PhaSeal Closed System Transfer Device P55 compatible with MRI machines, and if not, why?
No, the BD PhaSeal Closed System Transfer Device P55 is not MRI-compatible. This is explicitly stated in the manufacturer’s guidelines, likely due to the presence of materials or components that could interfere with MRI imaging or pose a safety risk in the magnetic field environment. Always verify compatibility with your facility’s MRI protocols before use.
What regulatory pathway was followed for the FDA clearance of this device, and what does that mean for its use in clinical settings?
The BD PhaSeal Closed System Transfer Device P55 received Special 510(k) clearance (K130197) under the FDA’s premarket notification process. This classification means the device was determined to be substantially equivalent to a legally marketed predicate device, ensuring it meets FDA safety and effectiveness requirements for its intended use in drug reconstitution and transfer procedures in general hospital settings. The clearance confirms its compliance with FDA regulations for Class II medical devices.