Skip to content

BD Totalys SlidePrep 491346

by Becton, Dickinson and Company

Ref 491346

BD Totalys SlidePrep 491346 is a microscope slide maker/stainer IVD (EU IVDR Class A; FDA Class III; FDA product code MKQ, Processor, Cervical Cytology Slide, Automated) made by Becton, Dickinson and Company, registered in EUDAMED on 14 Jul 2026 (Basic UDI-DI 038290HXVURKCHQ5), approved under FDA PMA P970018 on 17 Jun 1999 and listed in FDA GUDID since 25 Aug 2016 (UDI-DI 00382904913465), active as of 26 Oct 2026. 11 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE IVDR PMA

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

11 closed

Documents

None linked in EUDAMED

A group certificate may exist

PMA P970018

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 26 Oct 2026.

Regulatory status

as of registry sync 26 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDR EUDAMED Number038290HXVURKCHQ5 Basic UDI-DI 00382904913465UDI-DIDate14 Jul 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00382904913465 UDI-DI Date25 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA PMAAPPR GUDID from GUDID Approved NumberP970018 Date17 Jun 1999DecidedStatusActive

Official records

From the FDA record

Device description
BD Totalys SlidePrep
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 26 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 038290HXVURKCHQ5 registered 14 Jul 2026 Active
  • FDA PMA P970018 decided 17 Jun 1999 Active
  • FDA GUDID UDI-DI 00382904913465 listed 25 Aug 2016 Listed

Recalls

11 recalls · FDA

    • Terminated Z-0877-2017 FDA Class II initiated 12 Feb 2016

    BD has confirmed that a portion of BD SurePath" collection vials associated with specific production lots may contain caps that are cracked which can lead to leaking of the preservative fluid.

  • 5 recalls, same reason

    • Terminated Z-1815-2012 FDA Class III initiated 22 Mar 2012
    • Terminated Z-1813-2012 FDA Class III initiated 22 Mar 2012
    • Terminated Z-1811-2012 FDA Class III initiated 22 Mar 2012
    • Terminated Z-1814-2012 FDA Class III initiated 22 Mar 2012
    • Terminated Z-1812-2012 FDA Class III initiated 22 Mar 2012

    The PrepStain Syringing Pipettes may not dispense the minimum volume of 7.5 mL of the sample due to leaking. This event resulted in an increase in complaints of leaking syringing pipettes

  • 4 recalls, same reason

    • Terminated Z-2085-2012 FDA Class II initiated 8 Dec 2011
    • Terminated Z-2087-2012 FDA Class II initiated 8 Dec 2011
    • Terminated Z-2088-2012 FDA Class II initiated 8 Dec 2011
    • Terminated Z-2086-2012 FDA Class II initiated 8 Dec 2011

    Some Prep Stain Kit, 1.2 DiTi Cones have been found to be leaking and the PrepStain Preparation kits contain incorrect preventive maintenance (PM) instructions.

    • Terminated Z-1090-2009 FDA Unclassified (pre-2012) initiated 26 Sep 2008

    Software Error in the non-gyn program of some devices may cause non-gyn samples to be incorrectly transferred from centrifuge tubes to slides potentially result in mismatched patient results.

Timeline

14 dated events

  1. Recall initiated FDA recalls Z-2088-2012
  2. Recall initiated FDA recalls Z-2086-2012
  3. Recall initiated FDA recalls Z-1815-2012
  4. Recall initiated FDA recalls Z-1813-2012
  5. Recall initiated FDA recalls Z-1811-2012
  6. Recall initiated FDA recalls Z-1814-2012
  7. Recall initiated FDA recalls Z-1812-2012
  8. Recall initiated FDA recalls Z-0877-2017
  9. Listed FDA GUDID 00382904913465
  10. Registered EUDAMED 038290HXVURKCHQ5

4 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States FDA PMA Active

Specification

EUDAMED · GUDID

Trade name
Totalys EUDAMED
BD Totalys SlidePrep GUDID
Generic name
Microscope slide maker/stainer IVD
Model / Ref / Catalog
491346
Primary DI / UDI-DI
00382904913465
Basic UDI-DI
038290HXVURKCHQ5
PMA number
FDA product code
MKQ
EMDN code
W0202059002 Automated slide stainers
GMDN term
Microscope slide maker/stainer IVD
Device class
Class A EUDAMED
Class III GUDID
EU registration type
Standard device
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class A
GUDID
Class III

Device class is stated on each registry's own scale: Class A in the EU (EUDAMED), Class III in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under AUTOMATED SLIDE STAINERS.

Other devices from Becton, Dickinson and Company

See all devices from Becton, Dickinson and Company →

Properties

  • Professional testing
  • IVD instrument
  • Prescription use
  • Serial number
Other properties (22, all answered No)