← Back to catalogue

Beacon Care Package - Soft Tissue (17G)

FDA UDI

Class II (US FDA UDI)

by Varian Medical Systems, Inc

Identity

Trade Name
Beacon Care Package - Soft Tissue (17G) FDA UDI
Generic Name
Radiation therapy invasive marker lesion localization system FDA UDI
Device Name
The Beacon transponder is an implantable wireless device composed of an internal circuit and encapsulation materials. The internal circuit resonates in response to an external AC magnetic field. The Beacon Care package consists of three Beacon transponders, each with a dedicated introducer needle. The Beacon transponders are implanted in or near the treatment target. The resonance signal is used to measure the location of the transponder, by the Calypso System. The BCP-Soft Tissue many only be used with the Calypso System v3.0 or higher. FDA UDI
Model / Reference
ASM0607-002 FDA UDI
Description
The Beacon transponder is an implantable wireless device composed of an internal circuit and encapsulation materials. The internal circuit resonates in response to an external AC magnetic field. The Beacon Care package consists of three Beacon transponders, each with a dedicated introducer needle. The Beacon transponders are implanted in or near the treatment target. The resonance signal is used to measure the location of the transponder, by the Calypso System. The BCP-Soft Tissue many only be used with the Calypso System v3.0 or higher. FDA UDI

Identifiers

Primary DI / UDI-DI
00850011006139 FDA UDI
510(k) Number
K152761 FDA UDI
FDA Product Code
IYE FDA UDI
GMDN Term
Radiation therapy invasive marker lesion localization system FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
892.5050 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

Yes

FDA UDI

Single Use

Yes

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

No

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

No

FDA UDI
MRI Safety
MR Conditional FDA UDI

Dimensions & Sizes

Size
Needle Gauge — 17 Gauge FDA UDI

Category: Radiation therapy invasive marker lesion localization system

Beacon Care Package - Soft Tissue (17G) by Varian Medical Systems, Inc — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Radiation therapy invasive marker lesion localization system.

Cleared under the same submission

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI 2f97db69-9bf1-4ef1-bff2-71cb26f94f99 36 fields · synced May 31, 2026