Skip to content

Binary Anterior Cervical Plate System

by Genesys Spine

510(k) K192076

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK192076 Date29 Aug 2019ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
KWQ
Device Class
Class II
Regulation
21 CFR Part 888.3060
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Binary Anterior Cervical Plate System is an orthopedic device classified as an anterior cervical plate under the FDA’s product code KWQ. It is designed for temporary stabilization of the cervical spine during anterior spinal fusion procedures, providing structural support to the cervical vertebrae. The system includes plates with integrated locking mechanisms to secure screws, ensuring secure fixation in degenerative disc disease, spondylolisthesis, or traumatic cervical spine injuries. Its modular design allows for customizable screw placement to accommodate varying anatomical requirements.

The system is supplied as a sterile, single-use device and is intended for use in operating room settings by trained surgeons. It includes self-drilling, self-tapping screws in fixed and variable configurations, with primary screws measuring 3.75mm and recovery screws 4.25mm. Compliance with FDA 510(k) clearance (K192076) ensures adherence to regulatory standards for orthopedic spinal fixation devices. Proper storage requires maintaining sterility until immediate preoperative use, with no noted MRI compatibility restrictions.

Other devices from Genesys Spine

See all devices from Genesys Spine →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Binary Anterior Cervical Plate System used for?

    The Binary Anterior Cervical Plate System is designed for temporary stabilization of the cervical spine during anterior spinal fusion procedures. It provides structural support to the cervical vertebrae in cases of degenerative disc disease, spondylolisthesis, or traumatic cervical spine injuries. The modular plate and locking screws ensure secure fixation while accommodating varying anatomical needs.

  • How is the Binary Anterior Cervical Plate System supplied and prepared for use?

    The system is supplied as a sterile, single-use device, intended exclusively for operating room use by trained surgeons. It must remain sterile until immediate preoperative use. The modular design includes plates with integrated locking mechanisms and self-drilling, self-tapping screws in fixed and variable configurations, ensuring ease of placement without additional tools.

  • What screw sizes are included in the Binary Anterior Cervical Plate System?

    The system features primary screws with a diameter of 3.75mm and recovery screws with a diameter of 4.25mm. These screws are designed to secure the plate to the cervical vertebrae, providing stable fixation during spinal fusion procedures. The modular nature of the system allows for customizable screw placement to match anatomical requirements.

  • Is the Binary Anterior Cervical Plate System reusable or single-use?

    The Binary Anterior Cervical Plate System is explicitly designed as a single-use device. This ensures sterility and safety for each patient, reducing the risk of cross-contamination or device degradation from repeated use. Single-use devices are also aligned with best practices for orthopedic implants in surgical settings.

  • Are there any special storage requirements for the Binary Anterior Cervical Plate System?

    The system must be stored in a manner that maintains sterility until immediate preoperative use. No specific storage conditions (e.g., temperature or humidity) are mentioned beyond ensuring the packaging remains intact. Since it is single-use, it should not be reused or restocked after opening. Proper handling prevents contamination and ensures compliance with surgical protocols.