Bio-Modular Shoulder System CP550145

by Biomet Orthopedics, Inc.

Bio-Modular Shoulder System CP550145 is a device of GMDN type stem-fixed metallic humeral head prosthesis (FDA Class II) made by Biomet Orthopedics, Inc., cleared under FDA 510(k) K030710 on 4 Jun 2003 (1 earlier submission) and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 00880304114562), active as of 23 Oct 2026. 2 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

2 closed

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00880304114562 UDI-DI Date24 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK030710 Date4 Jun 2003DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K030710 decided 4 Jun 2003 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00880304114562 listed 24 Oct 2015 Listed

Recalls

2 recalls · FDA

    • Terminated Z-1859-2017 FDA Class II initiated 17 Feb 2017

    Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.

    • Terminated Z-0474-2013 FDA Class II initiated 1 Nov 2012

    The items in this lot are missing the ion implantation feature. The surface of the head may be softer and more prone to scratching, which in tum could potentially cause higher wear of the poly bearing. Increased wear could potentially lead to a shorter implant life.

Timeline

5 dated events

  1. Cleared FDA 510(k) K992119
  2. Cleared FDA 510(k) K030710
  3. Recall initiated FDA recalls Z-0474-2013
  4. Listed FDA GUDID 00880304114562
  5. Recall initiated FDA recalls Z-1859-2017

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Bio-Modular Shoulder System
Generic name
Stem-fixed metallic humeral head prosthesis
Model / Ref / Catalog
CP550145
Primary DI / UDI-DI
00880304114562
510(k) Number
FDA product code
HSD, MBF, KWS, KWT
GMDN term
Stem-fixed metallic humeral head prosthesis
Device class
Class II
Regulation number
888.3690, 888.3670, 888.3660, 888.3650
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Stem-fixed metallic humeral head prosthesis.

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)