Biofill infiltration cannula STS, Ø=2.5, L=150, 0H, Infiltration
by Human Med AG
Ref 580107
Biofill infiltration cannula STS, Ø=2.5, L=150, 0H, Infiltration (580107) is a liposuction system cannula (EU MDD Class IIa; FDA Class II; FDA product code QPB, System, Suction, Lipoplasty For Removal) made by Human Med AG, registered in EUDAMED on 2 Nov 2026 (Basic UDI-DI B-04260170881274), cleared under FDA 510(k) K082025 on 13 Aug 2008 and listed in FDA GUDID since 30 Jul 2025 (UDI-DI 04260170881274), active as of 7 Nov 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-04260170881274 04260170881274 | Date2 Nov 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04260170881274 | Date30 Jul 2025 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK082025 | Date13 Aug 2008 | StatusActive |
Official records
- EUDAMED public site B-04260170881274
- AccessGUDID record 04260170881274
- FDA 510(k) database K082025
From the FDA record
- Device description
- Biofill infiltration cannula, Ø=2.5mm, 0 Holes, L=15cm, Stainless Steel, Infiltration
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-04260170881274 registered 2 Nov 2026 Active
- FDA 510(k) K082025 decided 13 Aug 2008 Active
- FDA GUDID UDI-DI 04260170881274 listed 30 Jul 2025 Listed
Recalls
-
- Ongoing Z-1251-2025
The cannula tubes do not comply with the specification. The water jet emerging from the nozzle of the nonconforming cannulas may emerge as a spot jet rather than a fan-shaped spray jet.
Timeline
- Cleared FDA 510(k) K082025
- Recall initiated FDA recalls Z-1251-2025
- Listed FDA GUDID 04260170881274
- Registered EUDAMED B-04260170881274
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Biofill Infiltrationskanüle EUDAMEDBiofill infiltration cannula GUDID
- Generic name
- Liposuction system cannula, reusable
- Device name
- WAL cannula
- Model / Ref / Catalog
- 580107, STS, Ø=2.5, L=150, 0H, Infiltration
- Primary DI / UDI-DI
- 04260170881274
- Basic UDI-DI
- B-04260170881274
- 510(k) Number
- FDA product code
- QPB
- EMDN code
- L030101 Suction and irrigation surgical cannulas and handpieces, reusable
- GMDN term
- Liposuction system cannula, reusable
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 878.5040
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 580107 | STS, Ø=2.5, L=150, 0H, Infiltration |
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under SUCTION AND IRRIGATION SURGICAL CANNULAS AND HANDPIECES, REUSABLE.
- Panetti suction micro hook 10-807-12 by SPIGGLE & THEIS Medizintechnik GmbH
- Gimmi T.0044.10 by Gimmi GmbH
- Panetti ear drum suction dissector 10-801-12 by SPIGGLE & THEIS Medizintechnik GmbH
- WI-407-005R: Non-Sterile, Reusable, Micro Ear Forceps 80Mm Shaft, 4.0 X 0.8Mm Serrated Jaw, Left by WELDON INSTRUMENTS
- Canule aspiratrice Héparine Ø 2,5mm embout 4 Fig, 1 OH2541 by Société Française de Fabrication d'Instruments de Chirurgie (SFFIC)
- FRAZIER SUCTION TUBES CHARR./FR 6 17-058-08 by M.A. ARAIN AND BROTHERS (PVT) LTD.
- Gimmi T.0032.15 by Gimmi GmbH
- SCANLAN® Suction System Devices 9009-952 by SCANLAN INTERNATIONAL INC
- SCANLAN® Minimally Invasive Instrumentation 9009-914K by SCANLAN INTERNATIONAL INC
- Imukärki 6429810775HA93503B by Lasinpuhaltamo T:mi Harrin Lahja ja Lasi