Biomet® Patellar System 150802
Biomet Patellar System 150802 is a device of GMDN type metal-backed patella prosthesis (FDA Class II) made by Biomet Orthopedics, Inc., cleared under FDA 510(k) K171054 on 28 Jul 2017 (1 earlier submission) and listed in FDA GUDID since 23 Jul 2018 (UDI-DI 00887868241642), active as of 22 Oct 2026. 6 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00887868241642 | Date23 Jul 2018 | StatusListed |
| United States | FDA 510(k)SESE | NumberK171054 | Date28 Jul 2017 | StatusActive |
Official records
- AccessGUDID record 00887868241642
- FDA 510(k) database K171054
- FDA 510(k) database K833921
From the FDA record
- MRI safety
- MR Conditional
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K171054 decided 28 Jul 2017 Active
- FDA GUDID UDI-DI 00887868241642 listed 23 Jul 2018 Listed
Recalls
-
- Terminated Z-0938-2019
Vanguard Knee System Series-A Standard Patella a potential commingle that could result in the size of the implant not matching the size on the label.
-
- Terminated Z-2289-2018
Two lots of tibial bearings were commingled. There is a possibility that a 14mm tibial bearing is packaged in a box labeled as 12 mm tibial bearing and vice versa. This may lead to extension of surgery to find another implant.
-
- Terminated Z-2177-2018
One lot of 75mm tibial tray is potentially etched and labeled as a 79 mm tibial tray. This may lead to delay in surgery, or immediate revision surgery to remove an incorrectly sized tibial component after it has been cemented.
-
- Terminated Z-2183-2018
The label master file was errantly set up as a 63/37mm instead of a 63/67mm. There is no 63/37 size offered, and the product is laser marked with the correct size.
-
- Terminated Z-0627-2018
- Terminated Z-0628-2018
The affected AGC 2000 LP Patella products were over-molded leaving the outside diameter nonconforming to the print dimension.
Timeline
- Cleared FDA 510(k) K833921
- Cleared FDA 510(k) K171054
- Recall initiated FDA recalls Z-0627-2018
- Recall initiated FDA recalls Z-0628-2018
- Recall initiated FDA recalls Z-2183-2018
- Recall initiated FDA recalls Z-2177-2018
- Recall initiated FDA recalls Z-2289-2018
- Listed FDA GUDID 00887868241642
- Recall initiated FDA recalls Z-0938-2019
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Biomet® Patellar System
- Generic name
- Metal-backed patella prosthesis
- Model / Ref / Catalog
- 150802
- Primary DI / UDI-DI
- 00887868241642
- FDA product code
- MBV, OIY, HRY, JWH, MBH
- GMDN term
- Metal-backed patella prosthesis
- Device class
- Class II
- Regulation number
- 888.3560, 888.3530, 888.3565
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Similar devices
Other devices filed under FDA product code MBV (Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer).
- Total Knee System (K822583) by Richard'S Medical Equip., Inc.
- FREEMAN-SAMUELSON MARK II PRESS-FIT TOTAL KNEE REP by Protek, Inc.
- TRICON-M TOTAL KNEE SYSTEM by Richards Medical Co., Inc.
- RMC TOTAL KNEE SYSTEM by Richard'S Medical Equip., Inc.
- OFFSET TIBIAL TRAY by Biomet, Inc.
- FREEMAN-SAMUELSON MARK II PRESS-FIT TOTAL KNEE by Protek, Inc.
- MARK I TOTAL KNEE SYS. ARTHROPLASTY by Advanced Biosearch Assn.
- ICLH TIBIAL PLATEAU by Depuy, Inc.
- FREEMAN/SAMUELSON TOTAL KNEE by Depuy, Inc.
- TRICON M TOTAL KNEE SYSTEM by Richards Medical Co., Inc.