Skip to content

Biomet® Patellar System 150802

by Biomet Orthopedics, Inc.

Biomet Patellar System 150802 is a device of GMDN type metal-backed patella prosthesis (FDA Class II) made by Biomet Orthopedics, Inc., cleared under FDA 510(k) K171054 on 28 Jul 2017 (1 earlier submission) and listed in FDA GUDID since 23 Jul 2018 (UDI-DI 00887868241642), active as of 22 Oct 2026. 6 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

6 closed

Documents

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00887868241642 UDI-DI Date23 Jul 2018ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK171054 Date28 Jul 2017DecidedStatusActive

Official records

From the FDA record

MRI safety
MR Conditional
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K171054 decided 28 Jul 2017 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00887868241642 listed 23 Jul 2018 Listed

Recalls

6 recalls · FDA

    • Terminated Z-0938-2019 FDA Class II initiated 21 Dec 2018

    Vanguard Knee System Series-A Standard Patella a potential commingle that could result in the size of the implant not matching the size on the label.

    • Terminated Z-2289-2018 FDA Class II initiated 24 May 2018

    Two lots of tibial bearings were commingled. There is a possibility that a 14mm tibial bearing is packaged in a box labeled as 12 mm tibial bearing and vice versa. This may lead to extension of surgery to find another implant.

    • Terminated Z-2177-2018 FDA Class II initiated 18 May 2018

    One lot of 75mm tibial tray is potentially etched and labeled as a 79 mm tibial tray. This may lead to delay in surgery, or immediate revision surgery to remove an incorrectly sized tibial component after it has been cemented.

    • Terminated Z-2183-2018 FDA Class II initiated 11 May 2018

    The label master file was errantly set up as a 63/37mm instead of a 63/67mm. There is no 63/37 size offered, and the product is laser marked with the correct size.

  • 2 recalls, same reason

    • Terminated Z-0627-2018 FDA Class II initiated 25 Aug 2017
    • Terminated Z-0628-2018 FDA Class II initiated 25 Aug 2017

    The affected AGC 2000 LP Patella products were over-molded leaving the outside diameter nonconforming to the print dimension.

Timeline

9 dated events

  1. Cleared FDA 510(k) K833921
  2. Cleared FDA 510(k) K171054
  3. Recall initiated FDA recalls Z-0627-2018
  4. Recall initiated FDA recalls Z-0628-2018
  5. Recall initiated FDA recalls Z-2183-2018
  6. Recall initiated FDA recalls Z-2177-2018
  7. Recall initiated FDA recalls Z-2289-2018
  8. Listed FDA GUDID 00887868241642
  9. Recall initiated FDA recalls Z-0938-2019

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Biomet® Patellar System
Generic name
Metal-backed patella prosthesis
Model / Ref / Catalog
150802
Primary DI / UDI-DI
00887868241642
510(k) Number
FDA product code
MBV, OIY, HRY, JWH, MBH
GMDN term
Metal-backed patella prosthesis
Device class
Class II
Regulation number
888.3560, 888.3530, 888.3565
GUDID distribution status
In Commercial Distribution
MRI safety
MR Conditional

Similar devices

Other devices filed under FDA product code MBV (Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer).

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)