Biopsy Bracket 680-093
by Civco Medical Instruments Co., Inc.
Ref 680-093
Biopsy Bracket 680-093 is a needle guide (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Civco Medical Instruments Co., Inc., registered in EUDAMED on 28 May 2026 (Basic UDI-DI 0841436101TD102A4NJ), cleared under FDA 510(k) K970514 on 20 Jun 1997 and listed in FDA GUDID since 22 Aug 2017 (UDI-DI 00841436107532), active as of 23 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0841436101TD102A4NJ 00841436107532 | Date28 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00841436107532 | Date22 Aug 2017 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK970514 | Date20 Jun 1997 | StatusActive |
Official records
- EUDAMED public site 0841436101TD102A4NJ
- AccessGUDID record 00841436107532
- FDA 510(k) database K970514
From the FDA record
- Device description
- Reusable non-sterile transrectal needle guide bracket for use with Toshiba PVM-740RT and PVT-770 RT transducers
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0841436101TD102A4NJ registered 28 May 2026 Active
- FDA 510(k) K970514 decided 20 Jun 1997 Active
- FDA GUDID UDI-DI 00841436107532 listed 22 Aug 2017 Listed
Recalls
-
- Terminated Z-2946-2018
- Terminated Z-2947-2018
The assembly of the needle guides were found to be either missing adhesive or did not have adequate adhesive to hold the assembled cannula in place on the needle guide.
-
- Terminated Z-1054-2008
Incorrect Needle Guide- The individual pouches contained V53W Endocavity Needle guide(p/n/034-054) instead of the Shimadzu T/R Needle guide (p/n134-054).
Timeline
- Cleared FDA 510(k) K970514
- Recall initiated FDA recalls Z-1054-2008
- Listed FDA GUDID 00841436107532
- Recall initiated FDA recalls Z-2946-2018
- Recall initiated FDA recalls Z-2947-2018
- Registered EUDAMED 0841436101TD102A4NJ
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Biopsy Bracket
- Generic name
- Needle guide, reusable
- Device name
- Endocavity Guidance (Reusable bracket)
- Model / Ref / Catalog
- 680-093
- Primary DI / UDI-DI
- 00841436107532
- Basic UDI-DI
- 0841436101TD102A4NJ
- Direct marketing DI
- 20841436116026
- 510(k) Number
- FDA product code
- ITX
- EMDN code
- A018002 Needle guides
- GMDN term
- Needle guide, reusable
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Size
- Width — 1.2 InchLength — 1.4 Inch
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under NEEDLE GUIDES.
- Non-implantable, needle guide, reusable UA1232 by BK MEDICAL APS
- Single-Use Biplane Biopsy Guide UA1322-S14 by BK MEDICAL APS
- Fiducial Marker Grid Block Assembly 453530096543 by Philips Medical Systems Nederland B.V.
- SeeStar 12G 13312 by Apriomed AB
- Transperineal Guide Guided Angled Bracket 14G-23G 28-GG568 by Advance Medical Designs, Inc.
- SeeStar 17G 13317 by Apriomed AB
- InnoFine DEK-001 10631 by JingFang Precision Medical Device(Shenzhen) Co., Ltd.
- InnoFine JEM-070 by JingFang Precision Medical Device(Shenzhen) Co., Ltd.
- PEROUSE MEDICAL E63101DR VPEE63101DR by PEROUSE MEDICAL
- Needle Guide LNGC2022YX by Argon Medical Devices, Inc.