← Back to catalogue

Biopsy Forceps, Blakesley

EUDAMEDFDA UDI

Class I (EU MDR)

Ref BFS323061

by Joimax GmbH

Identity

Trade Name
Biopsy Forceps, Blakesley EUDAMED
Forceps FDA UDI
Generic Name
Rigid endoscopic biopsy forceps, reusable FDA UDI
Device Name
Biopsy Forceps, Blakesley EUDAMEDFDA UDI
Model / Reference
BFS323061 EUDAMEDFDA UDI
Description
Biopsy Forceps, Blakesley FDA UDI

Identifiers

Catalog Number
BFS323061 FDA UDI
Primary DI / UDI-DI
04250337103059 EUDAMEDFDA UDI
Basic UDI-DI
42503371FORCGRAG8 EUDAMED
B-04250337103059 EUDAMED
FDA Product Code
GEN FDA UDI
EMDN Code
L110602 NEUROSURGERY GRIPPERS, REUSABLE EUDAMED
GMDN Term
Rigid endoscopic biopsy forceps, reusable FDA UDI

Classification

Device Class
Class I EUDAMEDFDA UDI
Regulation Number
878.4800 FDA UDI
Market of Registration
Germany EUDAMED
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

EUDAMEDFDA UDI

Single Use

No

FDA UDI

Implantable

No

EUDAMEDFDA UDI

Reusable

Yes

EUDAMED

Contains Latex

No

EUDAMEDFDA UDI

Reprocessed

No

EUDAMED

CMR Substance

No

EUDAMED

Human-derived

No

EUDAMED

Human Tissues

No

EUDAMED

Animal Tissues

No

EUDAMED

Endocrine Disruptor

No

EUDAMED

Administering Medicine

No

EUDAMED

Measuring Function

No

EUDAMED

Incorporates Medicinal Product

No

EUDAMED

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

Yes

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

No

FDA UDI

Manufacturing Date

Yes

FDA UDI
Sterilization Method
Moist Heat or Steam Sterilization FDA UDI

Category: Flexible endoscopic biopsy forceps, reusable

Biopsy Forceps, Blakesley by Joimax GmbH — Class I — MDD, MDR, FDA UDI — listed in EUDAMED, FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Flexible endoscopic biopsy forceps, reusable.

Authorization Coverage (2 countries)

Regulatory Authorizations

European Union Active

CE/MDD

European Union Active

CE/MDR

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Manufacturer
Joimax GmbH
EUDAMED SRN
DE-MF-000009201

Sources (3)

  • EUDAMED 2c7486df-5468-4e3d-944c-53ceb02f20f6 61 fields · synced Jul 17, 2026
  • EUDAMED 7ee1b721-4a72-4503-aa20-2af4d28f1233 61 fields · synced May 19, 2026
  • FDA UDI 0a55994a-8c5e-4778-8638-5f99a18f008b 36 fields · synced May 30, 2026