Biotronik DN Unipolar PE-60/4-DN Electrode
510(k) K833098
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK833098 | Date19 Oct 1983 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Biotronik Dn Unipolar Pe-60/4-Dn &
- 510(k) Number
- FDA Product Code
- DTB
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3680
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
This device is a Permanent Pacemaker Electrode, designed for transvenous implantation to deliver pacing stimuli to the heart. It features a unipolar configuration with a 60-centimeter lead length and four distinct ring electrodes, enabling precise cardiac rhythm management in patients requiring permanent pacing support.
The Biotronik DN Unipolar PE-60/4-DN Electrode is intended for single-use and must be implanted under sterile conditions in a clinical setting. It is classified as a Class III device under FDA regulations and has received FDA 510(k) clearance as substantially equivalent to a predicate device. Storage requires adherence to manufacturer guidelines to maintain sterility and functionality prior to use.
Other devices from Biotronik Sales, Inc.
Questions
AI-generated answers, 18 Sep 2026
What is the primary use of the Biotronik DN Unipolar PE-60/4-DN Electrode in clinical practice?
This device is designed for transvenous implantation to deliver pacing stimuli to the heart in patients requiring permanent cardiac rhythm management. Its unipolar configuration and four ring electrodes allow for precise pacing support, making it suitable for long-term use in patients with bradycardia or other indications necessitating a permanent pacemaker system.
Is this pacemaker electrode intended for reuse, or is it meant to be used only once?
The Biotronik DN Unipolar PE-60/4-DN Electrode is explicitly labeled for single-use only. It must be implanted under sterile conditions in a clinical setting, and reuse is not permitted to maintain safety and efficacy standards.
How should this device be stored to ensure sterility and functionality before use?
Storage must follow the manufacturer’s guidelines to preserve sterility and functionality. Since it is single-use and intended for sterile implantation, it should be kept in its original packaging until immediately before use, in a clean, dry environment away from direct sunlight or extreme temperatures.
What is the length of the lead, and how does this affect its placement in the body?
The lead has a 60-centimeter length, which provides sufficient reach for transvenous implantation—typically inserted through a vein (e.g., subclavian or cephalic) and advanced into the heart. This length ensures flexibility for proper positioning while minimizing risks associated with overly long or short leads.
What regulatory pathway was followed for FDA clearance of this device?
The Biotronik DN Unipolar PE-60/4-DN Electrode received FDA 510(k) clearance under the Traditional Review pathway, with a decision classification of Substantially Equivalent (SESE) to a predicate device. It falls under Class III regulatory classification and was reviewed by the Cardiovascular (CV) Advisory Committee.