BLA-800A Beam Limiting Device

by Toshiba Medical Systems

510(k) K954310

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 5 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 5 Oct 2026. What this means

Regulatory status

as of registry sync 5 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK954310 Date18 Oct 1995ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 5 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Bla-800A
510(k) Number
FDA Product Code
KPW
Device Class
Class II
Regulation
21 CFR Part 892.1610
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The BLA-800A is a beam-limiting device designed for diagnostic X-ray systems, specifically categorized under the FDA’s product code KPW. As a collimator, it restricts the X-ray beam to the area of interest, reducing patient exposure and improving image quality by minimizing scatter radiation. This device is integrated into radiology imaging workflows to ensure precise and controlled radiation delivery during fluoroscopic procedures.

The BLA-800A is supplied as a reusable component for Toshiba Medical Systems’ Cath/Angio imaging systems and is intended for use in radiology settings. It operates on a 24V DC input with a power consumption of 35W and is classified as a Class II medical device under FDA regulations (21 CFR 892.1610). While no explicit sterility requirements are stated, it is typically handled in a clean environment to maintain functionality and hygiene. Authorized for use in the United States via FDA 510(k) clearance (K954310), this device adheres to radiology-specific standards for diagnostic imaging.

Other devices from Toshiba Medical Systems

See all devices from Toshiba Medical Systems →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the BLA-800A used for in diagnostic imaging?

    The BLA-800A is a beam-limiting device (collimator) designed specifically for diagnostic X-ray systems, particularly in fluoroscopic procedures. It restricts the X-ray beam to the precise area of interest, which minimizes scatter radiation and reduces unnecessary patient exposure while enhancing image clarity and quality.

  • Is the BLA-800A intended for single-use or reusable applications?

    The BLA-800A is supplied as a reusable component for Toshiba Medical Systems’ Cath/Angio imaging systems. While no explicit sterility requirements are stated in the documentation, it is recommended to handle the device in a clean environment to maintain both functionality and hygiene standards.

  • What power requirements does the BLA-800A have?

    The BLA-800A operates on a 24V DC input with a power consumption of 35W. These specifications ensure compatibility with Toshiba’s Cath/Angio imaging systems while maintaining efficient performance during fluoroscopic procedures.

  • How is the BLA-800A regulated in the United States?

    The BLA-800A is authorized for use in the U.S. through FDA 510(k) clearance (K954310), classified as a Class II medical device under 21 CFR 892.1610. This regulatory pathway confirms its substantial equivalence to a predicate device, ensuring compliance with radiology-specific standards for diagnostic imaging.

  • Which Toshiba imaging systems is the BLA-800A compatible with?

    The BLA-800A is integrated into Toshiba Medical Systems’ Cath/Angio imaging systems. Its design ensures seamless integration into radiology workflows, particularly for fluoroscopic procedures where precise beam control is essential for patient safety and image quality.