Blazer Dx-20 Bidirectional Steerable Diagnostic Catheter

by Boston Scientific 2 variants

510(k) K211375

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 25 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 25 Oct 2026. What this means

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK211375 Date10 Sep 2021ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 25 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DRF
FDA applicant
Boston Scientific Corporation
Device Class
Class II
Regulation
21 CFR Part 870.1220
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Blazer Dx-20 Bidirectional Steerable Diagnostic Catheter is a diagnostic catheter designed for electrophysiological studies. It features a duodecapolar configuration (20 electrodes) and is intended for intracardiac stimulation (pacing) and recording of electrical potentials within the cardiovascular system.

This catheter is supplied as a single-use, non-sterile device and is available in a 7F size. It is intended for use in electrophysiology laboratories and requires manual steering for precise positioning. The device is classified under FDA 510(k) clearance (K211375) and adheres to regulatory standards for diagnostic catheters, including MRI safety considerations as indicated by its classification. Storage and handling follow standard medical device protocols for reusable or single-use diagnostic tools.

Other devices from Boston Scientific

See all devices from Boston Scientific →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary use of the Blazer Dx-20 Bidirectional Steerable Diagnostic Catheter in clinical settings?

    The Blazer Dx-20 is designed specifically for electrophysiological studies, allowing clinicians to perform intracardiac stimulation (pacing) and precise recording of electrical potentials within the cardiovascular system. Its duodecapolar configuration (20 electrodes) enables detailed mapping and analysis of heart rhythms, which is essential for diagnosing arrhythmias and guiding ablation procedures.

  • Is the Blazer Dx-20 catheter intended for single-use or reusable applications, and how does this affect its sterility?

    The Blazer Dx-20 is supplied as a single-use device and is non-sterile as indicated in the manufacturer’s documentation. This means it must be sterilized by the facility prior to use if reprocessing is attempted, though the manufacturer does not recommend reuse. Clinicians should follow standard medical device sterilization protocols if reprocessing is necessary, though single-use is the intended approach.

  • What size and model variations are available for the Blazer Dx-20, and how does this impact its clinical application?

    The Blazer Dx-20 is currently available in a single size: 7 French (7F). This fixed size is optimized for precise navigation within the cardiovascular system, particularly for intracardiac recording and pacing during electrophysiological studies. The bidirectional steerability allows for flexible positioning, but the 7F diameter ensures compatibility with standard sheaths and access routes in electrophysiology labs.

  • How should the Blazer Dx-20 catheter be stored, and are there any special handling considerations?

    While the device itself is non-sterile, storage should follow standard medical device protocols for diagnostic catheters to maintain its integrity. The manufacturer does not specify unique storage conditions beyond typical environmental controls (e.g., protected from moisture, extreme temperatures, or physical damage). Since it is single-use, it should be stored in a clean, dry environment until use, and any reprocessing (if attempted) must adhere to validated sterilization procedures.

  • What regulatory pathway was followed for FDA clearance of the Blazer Dx-20, and what does this imply for clinicians?

    The Blazer Dx-20 received FDA 510(k) clearance (K211375) under the Traditional 510(k) pathway, with a decision of *Substantially Equivalent* (SESE) to a predicate device. This implies that the device was evaluated for safety and effectiveness against a previously cleared diagnostic catheter, ensuring compliance with FDA standards for electrophysiological tools. Clinicians can rely on this clearance as evidence of regulatory review for its intended use in electrophysiology labs.