Skip to content

Brahms Diagnostica DYNOTEST Anti-TPO

by Brahms Diagnostica, LLC

510(k) K992791

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK992791 Date12 Nov 1999ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
JZO
Device Class
Class II
Regulation
21 CFR Part 866.5870
Advisory Committee
Immunology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The DYNOTEST Anti-TPO is a System, Test, Thyroid Autoantibody designed for the detection of anti-thyroid peroxidase (anti-TPO) antibodies in human serum. It employs a competitive radioimmunoassay (RIA) format, where monoclonal antibodies bound to a coated tube compete with patient sample antibodies for radioactively labeled thyroid peroxidase, enabling quantitative measurement of autoantibody levels. This assay aids in the evaluation of autoimmune thyroid disorders, including Hashimoto’s thyroiditis and Graves’ disease, by identifying circulating anti-TPO antibodies.

This in vitro diagnostic device is supplied as a single-use kit and requires no sterilization beyond manufacturer controls. It is intended for use in clinical laboratories under regulated conditions, adhering to FDA 510(k) clearance (K992791) and Class II – Special Controls (product code JZO). Storage and handling follow standard laboratory protocols for radioactive materials, with no MRI safety considerations. The device’s performance is authorized under 21 CFR 866.5870 and is distributed exclusively for professional medical use.

Other devices from Brahms Diagnostica, LLC

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Brahms DYNOTEST Anti-TPO used for?

    The DYNOTEST Anti-TPO is designed to detect anti-thyroid peroxidase (anti-TPO) antibodies in human serum using a competitive radioimmunoassay (RIA). This test helps clinicians evaluate autoimmune thyroid disorders, such as Hashimoto’s thyroiditis and Graves’ disease, by quantifying circulating anti-TPO antibodies. The assay measures antibody levels indirectly by competing patient antibodies with radioactively labeled thyroid peroxidase for binding to monoclonal antibodies in a coated tube.

  • How is the Brahms DYNOTEST Anti-TPO supplied and what are its handling requirements?

    The DYNOTEST Anti-TPO is supplied as a single-use kit, meaning each test requires a new kit. No additional sterilization is required beyond the manufacturer’s controls, as it is intended for in vitro diagnostic use in clinical laboratories. Handling follows standard protocols for radioactive materials, as the assay employs a radiolabeled component. It is not intended for use outside regulated laboratory settings.

  • Is the Brahms DYNOTEST Anti-TPO sterile, and how should it be stored?

    The DYNOTEST Anti-TPO is not intended to be sterilized beyond the manufacturer’s internal controls, as it is a single-use diagnostic kit. Storage should adhere to standard laboratory protocols for radioactive materials, including proper shielding and containment. The kit should be stored in a secure, controlled environment to prevent contamination or degradation of the radiolabeled components. Always follow the manufacturer’s instructions for optimal performance.

  • Can the Brahms DYNOTEST Anti-TPO be reused, and what are the available sizes or models?

    The DYNOTEST Anti-TPO is explicitly designed for single-use only, and reuse is not recommended or supported by the manufacturer. This device does not come in multiple sizes or models; it is a standardized test kit for detecting anti-TPO antibodies in human serum. The assay format and components are consistent across all supplied kits to ensure reliable and reproducible results.

  • What regulatory approvals apply to the Brahms DYNOTEST Anti-TPO, and what are its safety considerations?

    The DYNOTEST Anti-TPO holds FDA 510(k) clearance under the reference number K992791, classified as a Class II device under special controls (product code JZO). It is authorized under 21 CFR 866.5870 and is intended exclusively for professional medical use in clinical laboratories. Safety considerations include adherence to standard radioactive material handling protocols, as the assay involves radiolabeled components. There are no MRI safety considerations, and the device must be used in compliance with FDA regulations and laboratory guidelines.