- Device class: Class II (US FDA)
- FDA product code: IYE

## Overview

*AI-generated summary, 2026-09-19. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The BrainScan Radiosurgery Module is a medical charged-particle radiation therapy system designed to accelerate high-energy charged particles (e.g., electrons and protons) for use in radiation therapy. It functions as a specialized component within a radiosurgery or radiotherapy treatment planning system, enabling precise targeting of lesions or tumors with focused radiation doses.

This module is intended for use in radiology settings and has been cleared by the FDA under the 510(k) pathway as substantially equivalent to prior devices. It is supplied as part of an integrated system and is not intended for standalone use. The device is classified under product code IYE and is regulated under 21 CFR 892.5050. No third-party review was required for this submission.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K920879 · decision 1992-12-29 · decision SESE · status: Active

## Recalls

- Z-2251-2009 ·  · terminated · initiated 2009-08-12 · matched through shared submission K920879, may concern other models: Failure to conduct important safety checks when using the BrainLab radiotherapy treatment planning software in combination with BrainLab conical collimators could result in unintended radiation outside the conical shaped field, which may lead to serious injury of the patient.

## Identifiers

- 510(k) Number: K920879 [FDA 510(k)]
- FDA product code: IYE [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 892.5050 [FDA 510(k)]
- Advisory committee: Radiology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: BrainScan Radiosurgery Module, Brainlab. deviCERTS medical device catalogue. https://devicerts.com/devices/brainscan-radiosurgery-module-iye (data as of 2026-11-19).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-19
- JSON: <https://devicerts.com/devices/brainscan-radiosurgery-module-iye.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/brainscan-radiosurgery-module-iye
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.