# Brio Neurostimulation System Leads, Adaptors, and Extensions

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/brio-neurostimulation-system-p140009>
- Manufacturer: [Abbott Medical](https://devicerts.com/manufacturers/abbott-medical) (United States)
- Name in the registry: SPINAL CORD STIMULATION LEADS, DEEP BRAIN STIMULATION LEADS, ADAPTORS, AND EXTENSIONS
- Device class: Class III (US FDA)
- FDA product code: MHY

## Overview

*AI-generated summary, 2026-09-18. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Brio Neurostimulation System Leads, Adaptors, and Extensions are electrical, implanted stimulators designed for deep brain and spinal cord stimulation. These devices are classified as Class III medical devices and include leads for bilateral stimulation of the subthalamic nucleus (STN) and ventral intermediate nucleus (VIM) of the thalamus, intended to manage advanced Parkinson’s disease symptoms and essential tremor unresponsive to medication.

These components are supplied sterile and intended for single-use implantation. They are regulated under FDA PMA approval (P140009) and are used in neurosurgical settings for adjunctive therapy in advanced neurological conditions. The system adheres to strict MRI safety guidelines and is distributed with detailed surgical instructions for proper placement and connection. Authorisations include FDA\_PMA, with specific product codes (MHY) and registration numbers listed in the OpenFDA database.

## Registrations and authorizations

- **PMA** · FDA PMA · United States · P140009 · decision 2015-06-12 · decision APPR · status: Active

## Recalls

- Z-0459-2026 · Class II · ongoing · initiated 2025-10-06: There is a potential issue affecting Eterna Spinal Cord Stimulation (SCS) Implantable Pulse Generators (IPGs), Model 32400 and Liberta RC Deep Brain Stimulation (DBS) Implantable Pulse Generators (IPGs), Model 62400 . These devicess may experience a loss of communication with the Clinician Programmer (CP) and/or the Patient Controller (PC).
- Z-2693-2017 · Class II · terminated · initiated 2017-06-02: The firm discovered a risk of loss of Neuromodulation therapy due to exposure of the IPG to monopolar electrosurgical devices (ESU) during medical procedures.
- Z-2694-2017 · Class II · terminated · initiated 2017-06-02: The firm discovered a risk of loss of Neuromodulation therapy due to exposure of the IPG to monopolar electrosurgical devices (ESU) during medical procedures.
- Z-2695-2017 · Class II · terminated · initiated 2017-06-02: The firm discovered a risk of loss of Neuromodulation therapy due to exposure of the IPG to monopolar electrosurgical devices (ESU) during medical procedures.
- Z-2696-2017 · Class II · terminated · initiated 2017-06-02: The firm discovered a risk of loss of Neuromodulation therapy due to exposure of the IPG to monopolar electrosurgical devices (ESU) during medical procedures.

## Identity

- Trade name: BRIO NEUROSTIMULATION SYSTEM [FDA PMA]
- Generic name: Stimulator, electrical, implanted, for parkinsonian tremor [FDA PMA]

## Identifiers

- PMA number: P140009 [FDA PMA]
- FDA product code: MHY [FDA PMA]

## Classification

- Device class: Class III [FDA PMA]
- Advisory committee: Neurology [FDA PMA]
- FDA decision: APPR [FDA PMA]

## Source and citation

- Cite as: Brio Neurostimulation System Leads, Adaptors, and Extensions, Abbott Medical. deviCERTS medical device catalogue. https://devicerts.com/devices/brio-neurostimulation-system-p140009 (data as of 2026-11-24).
- Data sources: [FDA PMA](https://open.fda.gov/apis/device/pma/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-06
- Statuses computed as of: 2026-11-24
- JSON: <https://devicerts.com/devices/brio-neurostimulation-system-p140009.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/brio-neurostimulation-system-p140009
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.