Skip to content

C. Diff Quik Chek Complete T30550C

by Techlab, Inc.

Ref T30550C

C. Diff Quik Chek Complete T30550C is a clostridium difficile antigen IVD (EU IVDR Class B; FDA Class I; FDA product code LLH, Reagents, Clostridium Difficile Toxin) made by Techlab, Inc., registered in EUDAMED on 2 Nov 2026 (Basic UDI-DI 857031002CDIFFAGTOX001SJ), cleared under FDA 510(k) K082499 on 26 Mar 2009 and listed in FDA GUDID since 7 Aug 2018 (UDI-DI 00857031002158), active as of 7 Nov 2026.

Active European Union and United States. Also listed in GUDID (US).

CE IVDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 7 Nov 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K082499

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDR EUDAMED Number857031002CDIFFAGTOX001SJ Basic UDI-DI 00857031002158UDI-DIDate2 Nov 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00857031002158 UDI-DI Date7 Aug 2018ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) GUDID from GUDID NumberK082499 Date26 Mar 2009IssuedStatusActive

Official records

From the FDA record

Device description
The TECHLAB® C. DIFF QUIK CHEK COMPLETE® test is a rapid membrane enzyme immunoassay for the simultaneous detection of Clostridium difficile glutamate dehydrogenase antigen and toxins A and B in a single reaction well. The test detects C. difficile antigen, glutamate dehydrogenase, as a screen for the presence of C. difficile and confirms the presence of toxigenic C. difficile by detecting toxins A and B in fecal specimens from persons suspected of having C. difficile disease. The test is to be used as an aid in the diagnosis of C. difficile disease. As with other C. difficile tests, results should be considered in conjunction with the patient history.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 857031002CDIFFAGTOX001SJ registered 2 Nov 2026 Active
  • FDA 510(k) K082499 decided 26 Mar 2009 Active
  • FDA GUDID UDI-DI 00857031002158 listed 7 Aug 2018 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K082499
  2. Listed FDA GUDID 00857031002158
  3. Registered EUDAMED 857031002CDIFFAGTOX001SJ

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
C. Diff Quik Chek Complete
Generic name
Clostridium difficile antigen IVD, kit, enzyme immunoassay (EIA)
Model / reference
T30550C
Primary DI / UDI-DI
00857031002158
Basic UDI-DI
857031002CDIFFAGTOX001SJ
510(k) Number
FDA product code
LLH
EMDN code
W0105011803 C.difficile gdh and toxin a/b combined detection
GMDN term
Clostridium difficile antigen IVD, kit, enzyme immunoassay (EIA)
Device class
Class B EUDAMED
Class I GUDID
Regulation number
866.2660
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class B
GUDID
Class I

Device class is stated on each registry's own scale: Class B in the EU (EUDAMED), Class I in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under CLOSTRIDIUM DIFFICILE.

Other devices from Techlab, Inc.

See all devices from Techlab, Inc. →

Properties

  • Single use
  • Contains substances of microbial origin
  • IVD kit
  • Professional testing
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
Other properties (18, all answered No)