# C253A

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/c253a-04573596214510>
- Manufacturer: [FUJIFILM Corporation](https://devicerts.com/manufacturers/fujifilm-corporation) (Japan)
- Device class: Class IIa (EU MDR); Class II (US FDA)
- FDA product code: ITX, IYO, IYN
- EMDN: Z110402010201 CURVILINEAR TRANSCUTANEOUS TWO–DIMENSIONAL ULTRASOUND PROBES (CONVEX–ARRAY)
- GMDN: Extracorporeal ultrasound imaging transducer, hand-held (40768)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 457359621C253A46 · UDI-DI 04573596214510 · registered 2026-02-13 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 04573596214510 · listed 2024-01-22 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K220295 · decision 2022-04-29 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K202422 · decision 2020-11-04 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K191233 · decision 2019-08-09 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K181376 · decision 2018-07-18 · decision SESE · status: Active · from GUDID

## Recalls

- Z-0189-2022 · Class II · ongoing · initiated 2021-10-14: Diagnostic ultrasound system with the specified software version and used in conjunction with a Fujifilm (formally Hitachi) transducer does not display the measurement results correctly with two cardiology measurement functions: Mitral Regurgitation Flow (MR Flow) Measurement; Mitral Valve (MV) Measurement. In addition there is an error in the instruction manual.
- Z-0192-2022 · Class II · ongoing · initiated 2021-10-14: When the ultrasound system is used in combination with a Fujifilm (formally Hitachi) transducer, there is an error in the calculation formula of Effective Regurgitant Orifice Area (EROA) when you perform MR Flow combined with Left Ventricular Outflow Tract Flow (LVOT Flow) after performing an echocardiogram. The incorrect value is displayed. In addition, the error appears in the instruction manual

## Identity

- Generic name: Extracorporeal ultrasound imaging transducer, hand-held [FDA GUDID (AccessGUDID)]
- Model / reference: 04573596214510 [EUDAMED]; C253A [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 04573596214510 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 457359621C253A46 [EUDAMED]
- Direct marketing DI: 04573596214510 [EUDAMED]
- 510(k) Number: K181376 [FDA GUDID (AccessGUDID)]; K191233 [FDA GUDID (AccessGUDID)]; K202422 [FDA GUDID (AccessGUDID)]; K220295 [FDA GUDID (AccessGUDID)]
- FDA product code: ITX [FDA GUDID (AccessGUDID)]; IYO [FDA GUDID (AccessGUDID)]; IYN [FDA GUDID (AccessGUDID)]
- EMDN code: Z110402010201 [EUDAMED]
- GMDN term: Extracorporeal ultrasound imaging transducer, hand-held (40768) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIa [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 892.1570 [FDA GUDID (AccessGUDID)]; 892.1560 [FDA GUDID (AccessGUDID)]; 892.1550 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Netherlands [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Sterilise before use: Yes [EUDAMED]; No [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: C253A, FUJIFILM Corporation. deviCERTS medical device catalogue. https://devicerts.com/devices/c253a-04573596214510 (data as of 2026-11-25).
- Data sources: [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-25
- JSON: <https://devicerts.com/devices/c253a-04573596214510.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/c253a-04573596214510
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.