Cable-Ready® 2232-50-20
by Zimmer, Inc.
Ref 00-2232-050-20Model 00-2232-050-18
Cable-Ready 2232-50-20 is an internal orthopaedic fixation system (EU MDR Class IIb; FDA Class II; FDA product code JDQ, Cerclage, fixation) made by Zimmer, Inc., registered in EUDAMED on 5 Jun 2026 (Basic UDI-DI 019108302021IM0063G), cleared under FDA 510(k) K151848 on 15 Jan 2016 and listed in FDA GUDID since 18 Aug 2017 (UDI-DI 00889024434257), active as of 22 Oct 2026.
Active
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number019108302021IM0063G 00889024434257 | Date5 Jun 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00889024434257 | Date18 Aug 2017 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK151848 | Date15 Jan 2016 | StatusActive |
Official records
- EUDAMED public site 019108302021IM0063G
- AccessGUDID record 00889024434257
- FDA 510(k) database K151848
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI 019108302021IM0063G registered 5 Jun 2026 Active
- FDA 510(k) K151848 decided 15 Jan 2016 Active
- FDA GUDID UDI-DI 00889024434257 listed 18 Aug 2017 Listed
Timeline
- Cleared FDA 510(k) K151848
- Listed FDA GUDID 00889024434257
- Registered EUDAMED 019108302021IM0063G
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Cable Ready Cable Grip System EUDAMEDCable-Ready® GUDID
- Generic name
- Internal orthopaedic fixation system, plate/screw, non-bioabsorbable, sterile
- Model / reference
- 00-2232-050-18 EUDAMED00-2232-050-20 EUDAMED2232-50-20 GUDID
- Primary DI / UDI-DI
- 00889024434257
- Basic UDI-DI
- 019108302021IM0063G
- 510(k) Number
- FDA product code
- JDQ
- EMDN code
- P09120302 Cerclage devices, wires and binders
- GMDN term
- Internal orthopaedic fixation system, plate/screw, non-bioabsorbable, sterile
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3010
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Size
- Length — 483 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 00-2232-050-18 00-2232-050-20 | 2232-50-20 |
| Device class | Class IIb | Class II |
| Supplied sterile | No | Yes |
| Sterilise before use | Yes | No |
| Implantable | Yes | No |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Supplied sterile UDI-DI 00889024434257: EUDAMED states No, FDA GUDID states Yes.
- Sterilise before use UDI-DI 00889024434257: EUDAMED states Yes, FDA GUDID states No.
Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under CERCLAGE DEVICES, WIRES AND BINDERS.
- Hex Button 400-783 2232-02-35 by Pioneer Surgical Technology Inc.
- Hex Button 400-777 2232-01-35 by Pioneer Surgical Technology Inc.
- ALAMBRE DE CERCLAJE C6113003 by SURGIVAL CO., S.A.U.
- Cerclage wire Cables CoCrWNi Alloy 611.105.01S by Synthes GmbH
- Cerclage Wire Cables Stainless Steel 298.801.01 by Synthes GmbH