CADD-Prizm PCS II Model 6101 Ambulatory Infusion System
510(k) K000842
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK000842 | Date8 Jun 2000 | StatusActive |
Recalls
-
- Terminated Z-0718-2007
The year of manufacture had been incorrectly entered as 1980 into the pumps software during the manufacture process. As a result the pump may go into an immediate 'Clock battery is Low/Service Immediately' or 'Clock Battery needs service soon' alarm message indicating that the pump requires servicing.
-
- Terminated Z-0980-03
Pump keyboard entries by the patient could have resulted in the patient having unintended access to programming screens and led to in improper drug dosage.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- FRN
- Device Class
- Class II
- Regulation
- 21 CFR Part 880.5725
- Advisory Committee
- General Hospital
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The CADD-Prizm PCS II Model 6101 is an ambulatory infusion pump classified as a Pump, Infusion under FDA nomenclature. It delivers intravenous, intra-arterial, subcutaneous, intraperitoneal, epidural, or subarachnoid infusions at continuous rates or via patient-controlled demand dosing, including applications such as patient-controlled analgesia (PCA).
This single-use, non-sterile device is intended for use in general hospital settings and requires programming for constant-rate or bolus-dose delivery. Supplied as a complete system, it adheres to FDA 510(k) clearance (K000842) under regulation 880.5725 and is designed for outpatient or home infusion therapy. No MRI safety information is specified.
Other devices from Sims Deltec, Inc.
Questions
AI-generated answers, 19 Sep 2026
What types of infusions can the CADD-Prizm PCS II Model 6101 deliver, and how is it programmed for use?
The CADD-Prizm PCS II Model 6101 is designed to deliver intravenous, intra-arterial, subcutaneous, intraperitoneal, epidural, or subarachnoid infusions. It supports both continuous-rate infusions and patient-controlled demand dosing, including applications like patient-controlled analgesia (PCA). Programming is required for constant-rate or bolus-dose delivery, making it versatile for outpatient or home infusion therapy in general hospital settings.
Is the CADD-Prizm PCS II Model 6101 intended for single-use or reusable applications, and what does this mean for sterility?
The CADD-Prizm PCS II Model 6101 is explicitly labeled as a single-use device, which means it is not meant to be reused after one patient use. Since it is non-sterile, it must be handled in a manner that maintains aseptic conditions during setup and infusion to prevent contamination, particularly in clinical environments like hospitals or outpatient care.
What regulatory pathway was followed for FDA clearance of the CADD-Prizm PCS II Model 6101, and what does this imply for its use?
The CADD-Prizm PCS II Model 6101 received FDA clearance through a 510(k) pathway, specifically under regulation 880.5725 for infusion pumps, with a decision code of SESE (Substantially Equivalent). This implies the device was determined to be comparable to a legally marketed predicate device, allowing it to enter the market without requiring a full premarket approval process. It is classified under the Pump, Infusion category and is intended for use in general hospital settings, including outpatient or home infusion therapy.
Does the CADD-Prizm PCS II Model 6101 have any safety considerations related to MRI environments?
The device documentation does not specify any MRI safety information, meaning there is no confirmed compatibility or safety data regarding its use in magnetic resonance imaging environments. Clinicians should assume the device is not MRI-safe unless explicitly stated otherwise, and avoid exposing it to MRI fields to prevent potential malfunctions or hazards.