Cadence™ 10209431
by Ascension Orthopedics, Inc.
Cadence 10209431 is a device of GMDN type fixed-bearing total ankle prosthesis (FDA Class II; FDA product code HSN, Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer) made by Ascension Orthopedics, Inc., cleared under FDA 510(k) K151459 on 31 Aug 2015 and listed in FDA GUDID since 12 Jan 2016 (UDI-DI 10381780239888), active as of 23 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10381780239888 | Date12 Jan 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK151459 | Date31 Aug 2015 | StatusActive |
Official records
- AccessGUDID record 10381780239888
- FDA 510(k) database K151459
From the FDA record
- Device description
- The Cadence™ Insert components are made out of highly cross-linked polyethylene UHMWPE, rigidly fixed to the Tibial Tray intra-operatively. In conjunction with the Talar Dome and Tibial Tray, the system is intended for both primary surgery and revision surgery applications which are designed to treat ankle arthritis through replacement of the ankle joint with a prosthesis, thereby reducing pain, restoring alignment, and allowing for movement at the replaced joint. These components are available in a variety of sizes and design configurations.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K151459 decided 31 Aug 2015 Active
- FDA GUDID UDI-DI 10381780239888 listed 12 Jan 2016 Listed
Recalls
-
- Terminated Z-1192-2017
Posterior tibial fractures have been reported.
-
- Terminated Z-2086-2016
As a result of an internal review of all labeling for the Cadence System, it was determined that the outer package label for the Size 5 Left Tibial Tray Implant reflects the material composition incorrectly. The labeling incorrectly reflects the material as Cobalt Chromium instead of Titanium.
Timeline
- Cleared FDA 510(k) K151459
- Listed FDA GUDID 10381780239888
- Recall initiated FDA recalls Z-2086-2016
- Recall initiated FDA recalls Z-1192-2017
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Cadence™
- Generic name
- Fixed-bearing total ankle prosthesis
- Model / Ref / Catalog
- 10209431
- Primary DI / UDI-DI
- 10381780239888
- 510(k) Number
- FDA product code
- HSN
- GMDN term
- Fixed-bearing total ankle prosthesis
- Device class
- Class II
- Regulation number
- 888.3110
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code HSN (PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER).
- Prophecy Surgical Planning System by Wright Medical Technology, Inc. (Stryker)
- Trabecular Metal® 00-4501-041-00 by Zimmer, Inc.
- Trabecular Metal® 00-4501-046-01 by Zimmer, Inc.
- DEPUY AGILITY LP TOTAL ANKLE PROSTHESIS by DEPUY ORTHOPAEDICS, INC.
- ANKLE INSTRUMENTS (FREEMAN-SWANSON) by Medishield, Inc.
- INVISION Total Ankle Revision System by Wrightmedicaltechnologyinc
- INBONE TOTAL ANKLE by Wrightmedicaltechnologyinc
- Vantage Total Ankle System by Exactech, Inc.
- INVISION 60002401 by WRIGHT MEDICAL TECHNOLOGY, INC.