Cal 3 CAL2351
Ref CAL2351
Cal 3 CAL2351 is an in vitro diagnostic device (EU IVDD general IVD; FDA Class II; FDA product code JIX, Calibrator, Multi-Analyte Mixture; EMDN category calibrators multicomponent (cc)) made by Randox Laboratories, Ltd., registered in EUDAMED on 28 Oct 2026 (Basic UDI-DI B-05055273200966), cleared under FDA 510(k) K053153 on 13 Jan 2006 and listed in FDA GUDID since 16 Sep 2016 (UDI-DI 05055273200966), active as of 7 Nov 2026. 6 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
4 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/IVDD EUDAMED | NumberB-05055273200966 05055273200966 | Date28 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number05055273200966 | Date16 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK053153 | Date13 Jan 2006 | StatusActive |
Official records
- EUDAMED public site B-05055273200966
- AccessGUDID record 05055273200966
- FDA 510(k) database K053153
Across registries
- EUDAMED Basic UDI-DI B-05055273200966 registered 28 Oct 2026 Active
- FDA 510(k) K053153 decided 13 Jan 2006 Active
- FDA GUDID UDI-DI 05055273200966 listed 16 Sep 2016 Listed
Certificates
No certifier certificate is listed. Devices of this class are self-declared by the manufacturer.
Recalls
-
- Ongoing Z-1759-2024
Randox Laboratories has identified that Inorganic Phosphate in Calibration Serum Level 3, CAL2351 & CAL10388, is running with a negative bias on RX Series instruments compared to other methods.
-
- Ongoing Z-0753-2024
Target for Alkaline Phosphatase (ALP) for the AMP optimized to IFCC 37C method has been mis-assigned for the RX Series instruments by approximately 10% on Quality Control and patient samples
-
- Ongoing Z-0752-2024
CK Total in Calibration Serum Level 3, CAL2351, is running with a positive bias on RX Series instruments compared to other methods experience a shift in Quality Control and patient sample recovery of up to 13%.
-
- Ongoing Z-0751-2024
There have been transcription errors on the Instructions For Use (IFU) of the Calibration Serum Level 3 (CAL2351 lot 1260UE, 1262UE and 1315UE) for target values of Bilirubin and Triglycerides, on the IFU of Human Assayed Multi-Sera Level 2 (HN1530) for TBIC taget value and on IFU of Human Assayed Multi-Sera Level 3 (HE 1532) for Lipase target value.
-
- Terminated Z-1563-2021
Randox can confirm a positive bias for Total Bilirubin and Direct Bilirubin of up to +15% across the assay ranges when using calibrator CAL2351, lot 1162UE. The positive bias has been attributed to bilirubin instability in the calibrator and is evident in both Quality Control (QC) and Patient samples.
-
- Terminated Z-2490-2019
Randox Laboratories realigned RX Analyser Series calibration targets by 10% for AST and 9% for ALT in line with the Mean of All Instrument method target for the Randox Calibration Serum Level 3 (for calibrator lot 961UE onwards).
Timeline
- Cleared FDA 510(k) K053153
- Listed FDA GUDID 05055273200966
- Recall initiated FDA recalls Z-2490-2019
- Recall initiated FDA recalls Z-1563-2021
- Recall initiated FDA recalls Z-0751-2024
- Recall initiated FDA recalls Z-0753-2024
- Recall initiated FDA recalls Z-0752-2024
- Recall initiated FDA recalls Z-1759-2024
- Registered EUDAMED B-05055273200966
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Calibration Serum Level 3 (Cal 3) EUDAMEDCal 3 GUDID
- Generic name
- Multiple-type clinical chemistry analyte profile IVD, calibrator
- Model / Ref / Catalog
- CAL2351
- Primary DI / UDI-DI
- 05055273200966
- Basic UDI-DI
- B-05055273200966
- 510(k) Number
- FDA product code
- JIX
- EMDN code
- W0101050301 Calibrators multicomponent (cc)
- GMDN term
- Multiple-type clinical chemistry analyte profile IVD, calibrator
- Device class
- Class IVD General EUDAMEDClass II GUDID
- Regulation number
- 862.1150
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Northern Ireland
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IVD General | Class II |
Similar devices in this category
Other devices filed under CALIBRATORS MULTICOMPONENT (CC).
- Calibrant Fluid Pack i20CP200 by Edan Instruments,Inc.
- Plasma Calibrator Set 92026/XT2 by Chromsystems Instruments & Chemicals GmbH
- Calibrant Fluid Pack CP100 by Edan Instruments,Inc.
- SYNCHRON Systems CAL 1 Calibrator 1 468405 by Beckman Coulter, Inc.
- SYNCHRON Systems AQUA CAL 1 471288 by Beckman Coulter, Inc.
- Plasma Calibrator Set 92053 by Chromsystems Instruments & Chemicals GmbH
- Dimension Vista® ENZ 2 CAL 10475527 KC321 by Siemens Healthcare Diagnostics Inc.
- Dimension® CHEM II Calibrator 10444997 DC20 by Siemens Healthcare Diagnostics Inc.
- Revogene® Check 610220 by Meridian Bioscience Inc.
- Alinity 08P7001 by Abbott