Skip to content

Calibrating Solution for ABL-1 & 2

by Fisher Scientific Co., LLC 510(k)

Active United States

510(k) K831021

Regulatory status

as of 29 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK831021 Date16 Jun 1983ClearedStatusActive

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 6 Oct 2026.

Specification

510(k)

510(k) Number
FDA Product Code
CHL
Device Class
Class II
Regulation
21 CFR Part 862.1120
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Calibrating Solution designed for use with blood gas analyzers (ABL-1 & ABL-2 systems) to ensure accurate measurement of partial pressures of carbon dioxide (PCO₂) and oxygen (PO₂), as well as blood pH in whole blood, serum, or plasma. It serves as a reference standard to validate and calibrate the performance of electrode-based blood gas measurement systems, maintaining precision in clinical chemistry diagnostics.

The solution is supplied as a liquid reagent for single-use calibration procedures in clinical laboratories or point-of-care settings. It is classified under FDA’s Electrode Measurement, Blood-Gases (PCO₂, PO₂) and Blood pH category (regulation number 862.1120) and holds a Traditional 510(k) clearance (K831021) for substantial equivalence in clinical chemistry applications. No sterility or MRI safety information is specified, and storage conditions are not detailed in the regulatory data.

Other devices from Fisher Scientific Co., LLC

See all devices from Fisher Scientific Co., LLC →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of this calibrating solution in clinical settings?

    This calibrating solution is designed specifically to validate and calibrate blood gas analyzers (ABL-1 & ABL-2 systems) for accurate measurement of partial pressures of carbon dioxide (PCO₂) and oxygen (PO₂), as well as blood pH. It serves as a reference standard to ensure the precision of electrode-based measurements in whole blood, serum, or plasma, which is critical for reliable clinical chemistry diagnostics.

  • Is this solution intended for single-use or repeated use in calibration procedures?

    The solution is supplied as a liquid reagent explicitly for single-use calibration procedures. This design ensures consistency and prevents cross-contamination between calibration cycles, which is important for maintaining accurate measurement standards in clinical laboratories or point-of-care settings.

  • What regulatory pathway was followed for this device’s clearance, and what does that mean for its use?

    The device holds a Traditional 510(k) clearance (K831021) under FDA’s Electrode Measurement, Blood-Gases (PCO₂, PO₂) and Blood pH category (regulation number 862.1120). This means it was determined to be substantially equivalent to a legally marketed predicate device, ensuring it meets established safety and performance standards for clinical chemistry applications. The clearance does not imply sterility or MRI safety, so users should follow manufacturer guidelines for handling.

  • Where and how is this solution typically used, and what sample types does it support?

    This solution is used in clinical laboratories or point-of-care settings to calibrate blood gas analyzers (ABL-1 & ABL-2 systems). It is compatible with whole blood, serum, or plasma samples, ensuring accurate measurement of PCO₂, PO₂, and pH—key parameters for diagnosing and monitoring respiratory, metabolic, and acid-base disorders.

  • Are there any specific storage instructions or considerations mentioned for this calibrating solution?

    The provided regulatory data does not include explicit storage conditions for this solution. However, since it is a liquid reagent for single-use calibration, it is advisable to follow the manufacturer’s (Fisher Scientific) recommended storage guidelines—typically involving protection from extreme temperatures, light exposure, and contamination—to maintain its stability and accuracy until use.