Cancellous Screw 8153-41-040
Ref 815341040
Cancellous Screw 8153-41-040 (815341040) is an orthopaedic bone screw (EU MDD Class IIb; FDA Class II) made by Biomet Orthopedics, Inc., registered in EUDAMED on 24 Oct 2026 (Basic UDI-DI B-00887868545320) and listed in FDA GUDID since 7 Sep 2022 (UDI-DI 00887868545320), active as of 7 Nov 2026.
Active
CE MDD
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00887868545320 00887868545320 | Date24 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00887868545320 | Date7 Sep 2022 | StatusListed |
Official records
- EUDAMED public site B-00887868545320
- AccessGUDID record 00887868545320
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-00887868545320 registered 24 Oct 2026 Active
- FDA GUDID UDI-DI 00887868545320 listed 7 Sep 2022 Listed
Timeline
- Listed FDA GUDID 00887868545320
- Registered EUDAMED B-00887868545320
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Cancellous Screw
- Generic name
- Orthopaedic bone screw, non-bioabsorbable, non-sterile
- Device name
- ALPS Hex 4_0mm cancellous nonlocking screw
- Model / Ref / Catalog
- 815341040, 8153-41-040
- Primary DI / UDI-DI
- 00887868545320
- Basic UDI-DI
- B-00887868545320
- FDA product code
- HWC, HRS, HTN, JDW, KTT, LXT, HTY, HSB
- EMDN code
- P09120602 Cancellous screws
- GMDN term
- Orthopaedic bone screw, non-bioabsorbable, non-sterile
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3040, 888.3030, 888.3020
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 815341040 | 8153-41-040 |
| Device class | Class IIb | Class II |
| Implantable | Yes | No |
Similar devices in this category
Other devices filed under CANCELLOUS SCREWS.
- Mpact Acetabular System 01.32.6535 by Medacta International SA
- 6,5 MM X 45 MM CANCELLOUS SCREW TITANIUM FULL THREAD TM08916545 by Tulpar Tıbbi Ürünler İthalat İhracat Sanayi ve Ticaret L.T.D Ş.T.İ
- 4.0mm Cancellous Screw, Fully Threaded T52004044 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- NCB® 02.02154.026 by Zimmer, Inc.
- LOQTEQ® SP 3825-54-2 by aap Implantate AG
- LOQTEQ® SP 3825-38-2 by aap Implantate AG
- Omni 144-35122 by Extremity Medical, LLC
- Omni Stable AF 144-35156 by Extremity Medical, LLC
- 6.5mm Cancellous Screw, Fully Threaded S52006570 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- Traufix 107.28 by FIXIER SA DE CV