Cancellous Screw 8153-41-042
Ref 815341042
Cancellous Screw 8153-41-042 (815341042) is an orthopaedic bone screw (EU MDD Class IIb; FDA Class II) made by Biomet Orthopedics, Inc., registered in EUDAMED on 24 Oct 2026 (Basic UDI-DI B-00887868545337) and listed in FDA GUDID since 7 Sep 2022 (UDI-DI 00887868545337), active as of 7 Nov 2026.
Active
CE MDD
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00887868545337 00887868545337 | Date24 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00887868545337 | Date7 Sep 2022 | StatusListed |
Official records
- EUDAMED public site B-00887868545337
- AccessGUDID record 00887868545337
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-00887868545337 registered 24 Oct 2026 Active
- FDA GUDID UDI-DI 00887868545337 listed 7 Sep 2022 Listed
Timeline
- Listed FDA GUDID 00887868545337
- Registered EUDAMED B-00887868545337
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Cancellous Screw
- Generic name
- Orthopaedic bone screw, non-bioabsorbable, non-sterile
- Device name
- ALPS Hex 4_0mm cancellous nonlocking screw
- Model / Ref / Catalog
- 815341042, 8153-41-042
- Primary DI / UDI-DI
- 00887868545337
- Basic UDI-DI
- B-00887868545337
- FDA product code
- HTN, HWC, KTT, HTY, JDW, HRS, HSB, LXT
- EMDN code
- P09120602 Cancellous screws
- GMDN term
- Orthopaedic bone screw, non-bioabsorbable, non-sterile
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3030, 888.3040, 888.3020
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 815341042 | 8153-41-042 |
| Device class | Class IIb | Class II |
| Implantable | Yes | No |
Similar devices in this category
Other devices filed under CANCELLOUS SCREWS.
- CONMED C2611 by Conmed Corporation
- Traufix 107.18 by FIXIER SA DE CV
- Omni Stable AF 144-35158 by Extremity Medical, LLC
- Omni 144-28116 by Extremity Medical, LLC
- Mpact Acetabular System 01.32.6520 by Medacta International SA
- 4.0mm Cancellous Screw, Fully Threaded T52004044 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- NCB® 02.02154.030 by Zimmer, Inc.
- NCB® 02.03154.042 by Zimmer, Inc.
- 4,5 MM X 20 MM CANCELLOUS SCREW TITANIUM FULL THREAD STERILE TM08924520 by Tulpar Tıbbi Ürünler İthalat İhracat Sanayi ve Ticaret L.T.D Ş.T.İ
- Mpact Extension 01.43.0050 by Medacta International SA