Skip to content

CapsoAccess

by CapsoVision, Inc.

Ref CDAS3

CapsoAccess (CDAS3) is a video capsule endoscopy system capsule (EU MDR Class I; FDA Class II; FDA product code NEZ, System, Imaging, Gastrointestinal, Wireless, Capsule) made by CapsoVision, Inc., registered in EUDAMED on 22 Dec 2021 (Basic UDI-DI 086777000023CDAS3QG), cleared under FDA 510(k) K192662 on 14 Feb 2020 (2 earlier submissions) and listed in FDA GUDID since 17 Jul 2018 (UDI-DI 00867770000230), active as of 22 Oct 2026. 3 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

3 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number086777000023CDAS3QG Basic UDI-DI 00867770000230UDI-DIDate22 Dec 2021RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK192662 Date14 Feb 2020DecidedStatusActive
United StatesGUDID listing GUDID Number00867770000230 UDI-DI Date17 Jul 2018ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Capsule Data Access System
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 086777000023CDAS3QG registered 22 Dec 2021 Active
  • FDA 510(k) K192662 decided 14 Feb 2020 Active· +2 more in the status table
  • FDA GUDID UDI-DI 00867770000230 listed 17 Jul 2018 Listed

Recalls

3 recalls · FDA

    • Terminated Z-2536-2020 FDA Class II initiated 26 Feb 2020

    Ingestible video capsule system has capsule with incorrect capture mode which will not record data when the capsule is ingested by patients. If used, there is a risk of delay of diagnosis and the patient may need to repeat the exam.

    • Terminated Z-1827-2020 FDA Class II initiated 18 Oct 2019

    Capsule Endoscopy System: a defect present in the capsule window may be stressed through the production process and in the final package, which could cause the housing of the capsule to crack and leak when ingested. Fluid from the patient could leak in to the capsule, which may damage components inside the capsule and the patient data may not be retrieved; the patient may need to repeat the exam.

    • Terminated Z-2073-2020 FDA Class II initiated 3 Jul 2019

    Possible mis-labeling of the device with incorrect serial number labels which may result in a patient's misdiagnosis.

Timeline

8 dated events

  1. Cleared FDA 510(k) K161773
  2. Listed FDA GUDID 00867770000230
  3. Cleared FDA 510(k) K183192
  4. Recall initiated FDA recalls Z-2073-2020
  5. Recall initiated FDA recalls Z-1827-2020
  6. Cleared FDA 510(k) K192662
  7. Recall initiated FDA recalls Z-2536-2020
  8. Registered EUDAMED 086777000023CDAS3QG

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Video capsule endoscopy system capsule
Model / Ref / Catalog
CDAS3 EUDAMED
3 GUDID
2668 GUDID
Primary DI / UDI-DI
00867770000230
Basic UDI-DI
086777000023CDAS3QG
FDA product code
NEZ
EMDN code
G030701 Gastrointestinal imaging diagnostic devices
GMDN term
Video capsule endoscopy system capsule
Device class
Class I EUDAMED
Class II GUDID
Regulation number
876.1300
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
CDAS3
GUDID
3
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000008446
Authorised representative
MedDevConsult GmbH DE-AR-000005877

Similar devices in this category

Other devices filed under GASTROINTESTINAL ENDOSCOPY, DIAGNOSTIC DEVICES.

Other devices from CapsoVision, Inc.

  • CapsoCloud 3

    Class II
  • CapsoView 4

    Class II
  • CE Deliver DLV

    Class II
  • CapsoView (CVV)

    Class II

See all devices from CapsoVision, Inc. →

Properties

  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (22, all answered No)