# CapsoAccess

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/capsoaccess-cdas3>
- Manufacturer: [CapsoVision, Inc.](https://devicerts.com/manufacturers/capsovision-inc) (United States)
- Device class: Class I (EU MDR); Class II (US FDA)
- FDA product code: NEZ
- EMDN: G030701 GASTROINTESTINAL IMAGING DIAGNOSTIC DEVICES
- GMDN: Video capsule endoscopy system capsule (38068)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 086777000023CDAS3QG · UDI-DI 00867770000230 · registered 2021-12-22 · status: Active
- **GUDID** · FDA 510(k) · United States · K192662 · decision 2020-02-14 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K183192 · decision 2019-04-19 · decision SESE · status: Active · from GUDID
- **GUDID** · GUDID listing · United States · UDI-DI 00867770000230 · listed 2018-07-17 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K161773 · decision 2016-10-21 · decision SESE · status: Active · from GUDID

## Recalls

- Z-2536-2020 · Class II · terminated · initiated 2020-02-26: Ingestible video capsule system has capsule with incorrect capture mode which will not record data when the capsule is ingested by patients. If used, there is a risk of delay of diagnosis and the patient may need to repeat the exam.
- Z-1827-2020 · Class II · terminated · initiated 2019-10-18: Capsule Endoscopy System: a defect present in the capsule window may be stressed through the production process and in the final package, which could cause the housing of the capsule to crack and leak when ingested. Fluid from the patient could leak in to the capsule, which may damage components inside the capsule and the patient data may not be retrieved; the patient may need to repeat the exam.
- Z-2073-2020 · Class II · terminated · initiated 2019-07-03: Possible mis-labeling of the device with incorrect serial number labels which may result in a patient's misdiagnosis.

## Identity

- Generic name: Video capsule endoscopy system capsule [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: CDAS3 [EUDAMED]; 3 [FDA GUDID (AccessGUDID)]; 2668 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00867770000230 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 086777000023CDAS3QG [EUDAMED]
- 510(k) Number: K161773 [FDA GUDID (AccessGUDID)]; K183192 [FDA GUDID (AccessGUDID)]; K192662 [FDA GUDID (AccessGUDID)]
- FDA product code: NEZ [FDA GUDID (AccessGUDID)]
- EMDN code: G030701 [EUDAMED]
- GMDN term: Video capsule endoscopy system capsule (38068) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class I [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 876.1300 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: France [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: CapsoAccess, CapsoVision, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/capsoaccess-cdas3 (data as of 2026-11-19).
- Data sources: [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-19
- JSON: <https://devicerts.com/devices/capsoaccess-cdas3.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/capsoaccess-cdas3
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.